A. uDL1 Equipment Specifications
Operating Temperature
Charging Temperature
Storage Temperature
Humidity
Maximum Altitude
Pollution Degree
Size
Weight
Enclosure
Measurement Type
Analog Ranges (DC & AC)
AC Rejection on DC Readings
Input Impedance
External Analog Channels
Lightning Immunity
Temp. Measurement Accuracy
DC Measurement Accuracy
AC Measurement Accuracy
Accuracy Aging
ADC Resolution
Memory Size
Battery
GPS Receiver
Output File Data Resolution
Technical assistance may be obtained from:
Attn: Service Department
Mobiltex Data Ltd.
th
3640-26
Street NE
Calgary, AB T1Y 4T7
Canada
Tel: (403)291-2770
Main Website:
http://www.cortalk.com
Service Website:
http://www.mobiltex.com/service
MOBILTEX® DATA LTD.
Calgary, Alberta
www.corTalk.com
-20 to +60 C (-4 to +140 F)
0 to +40 C (32 to +104 F)
-40 to +70 C (-40 to +158 F)
0 to 100% RH non-condensing
5000 meters above sea level
1
89mm x 40mm x 18mm (3.5" x 1.6" x 0.72")
75 grams (2.7 oz)
UV stable, wide temperature polycarbonate
Category 2 (as per CSA C22.2 – 61010)
+/- 150mVDC, 110mV true RMS AC, 150mVpeak
+/- 20VDC, 14V true RMS AC, 20Vpeak
+/-150VDC, 106V true RMS AC, 150Vpeak
>65dB @ 50/60Hz
>20Mohm
1 galvanically isolated, high impedance
Survives multiple 20KV 10mS surges
+/-4 C (+/-7 F) over -20 to +60 C (-4 to +140 F)
over -20 to +60 C (-4 to +140 F)
low range: +/-0.25% + 100uV
med range: +/-0.5% + 12mV
high range (-75V to +75V): +/-0.5% + 100mV
high range (<-75V and >+75V): +/-1% + 100mV
over -20 to +60 C (-4 to +140 F)
low range: +/-0.3% + 80uV, 180uV floor
med range: +/-0.65% + 10mV, 22mV floor
high range (-75V to +75V): +/-0.65% + 80mV, 170mV floor
high range (<-75V and >+75V): +/-1% + 80mV, 170mV floor
+/-0.13% per year
16 bits
Up to 500,000 readings (Basic model)
Up to 1,000,000 readings (Advanced G1 model)
Up to 2,000,000 readings (Advanced G2 model)
Internal Li-Ion (Not user replaceable)
20-channel SiRFStarIII (Advanced G1 model)
72-channel u-blox M8 (Advanced G2 model)
1uV for AC and DC readings
0.1 for temperature readings
0.00001 for GPS position
TITLE: uDL1 Configuration and Operation Guide
DOCUMENT NO.:
SHEET:
UDL1-MAN-001
REV:
26 of 26
1.07