Dimensions -
All dimensional tolerances are 0" to 1/16 unless otherwise stated
Wiring Location
Front of hood
Dimmable
Halogen
Lights
A
Washable Aluminum Filters
Duct †
Model
UPC#
SHL36
47036
8
SHL42
47042
10
SHL48
47048
10
Choosing the right remote mount blower
SHL36
Model
Location
FX 8
interior
FX 8XL
interior
FKD 8XL
interior
FKD 10XL
interior
RVF 8XL
exterior
RE 8XL
exterior
RE 10XL
exterior
SHL42
Model
Location
FX 8
interior
FX 8XL
interior
FKD 8XL
interior
FKD 10XL
interior
RVF 8XL
exterior
RE 8XL
exterior
RE 10XL
exterior
SHL48
Model
Location
FX 10
interior
FX 10XL
interior
FKD 10
interior
FKD 10XL
interior
FKD 12XL**
interior
RE 10XL
exterior
3" (76.2mm)
4"
(101.6mm)
Speed/Light
Controls
B
C
E
A
B
C
34 1/2
22
6
40 1/2
22
6
46 1/2
22
6
Airflow
Mounting
Airflow †
at 0"
inline
481
inline
521
inline
836
inline
1266
wall
435
roof/wall
409
roof/wall
753
Airflow
Mounting
Airflow †
at 0"
inline
481
inline
521
inline
836
inline
1266
wall
435
roof/wall
409
roof/wall
753
Airflow
Mounting
Airflow †
at 0"
inline
521
inline
590
inline
910
inline
1266
inline
2016
roof/wall
753
SGHL 30 & SGHL 36 Dimensions
Wiring Location
Front of hood
Speed/Light Controls
Dimmable
Halogen
Lights
Duct
1" (25.4mm)
Washable Aluminum Filters
E
Model
UPC#
3
SGHL30
47530
3
SGHL36
47536
3
SGHL30
Typical
Model
430
FX 6*
480
FX 6XL
740
FX 8XL
1175
RE 6*
392
RE 8XL
356
RVF 6*
730
RVF 6XL
SGHL36
Typical
Model
430
FX 8XL
480
FKD 8XL
740
RE 8XL
1175
RE 10XL
392
RVF 8XL
356
730
† Typical airflow is an estimate based on a system with 20' of duct,
Typical
two 90˚ elbows, a backdraft damper, roof cap and filters.
470
* Fans will meet most local code requirements but will produce less
540
than Fantech's recommended ventilation rate of 100 cm per foot of hood
780
width.
1060
1460
** Requires larger speed control. Contact Fantech Customer Service
720
for recommendations.
7/8" (22.23mm)
2.25"
(57.15mm)
F
SGHL30 - F=15" (381mm)
SGHL36 - F=18" 457.2mm)
B
A
Duct †
A
B
6
28 1/2
18
8
34 1/2
18
Airflow
Location
Mounting
interior
inline
interior
inline
interior
inline
exterior
roof/wall
exterior
roof/wall
exterior
wall
exterior
wall
Airflow
Location
Mounting
interior
inline
interior
inline
exterior
roof/wall
exterior
roof/wall
exterior
wall
Duct
1"
(25.4mm)
C
E
C
E
4
3
4
3
Typical
Airflow †
at 0"
257
190
392
275
521
320
227
205
409
356
242
200
381
330
Typical
Airflow †
at 0"
521
320
836
740
409
356
753
730
435