Fantech FIT 70E Installation, Operation And Maintenance Manual
Fantech FIT 70E Installation, Operation And Maintenance Manual

Fantech FIT 70E Installation, Operation And Maintenance Manual

Fresh air appliance
Hide thumbs Also See for FIT 70E:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Installation, Operations, and Maintenance Manual
Manuel d'installation, de fonctionnement et de maintenance
FIT 70E
®
Fresh Air Appliance (FAA/ERV)
Appareil d'air frais (AAF/VRE)
PARTS IN THE BOX
Energy Recovery Ventilator Fit70E, 1 pc
Ceiling bracket, 1 pc
Angle brackets, 2 pcs
External Damper Wire harness, 1 pc
Operation and Installation Manual, 1 pc
PIÈCES DANS LA BOÎTE
Ventilateur récupérateur d'énergie Fit70E, 1 pc
Support muraux, 1 pc
Équerre d'assemblage, 2 pcs
Faisceau de câbles de clapet externe, 1 pc
Manuel d'installation, 1 pc
Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of
such requirements, with the current edition of the National Building Code, and / or ASHRAE's "Good Engineering Practices".
Votre système de ventilation doit être installé conformément aux exigences de la province où vous habitez ou, à défaut de
telles exigences, conformément à l'édition actuelle du Code national du bâtiment du Canada ou aux « méthodes d'ingénierie
appropriées » de l'ASHRAE.
United States
10048 Industrial Blvd., Lenexa, KS, 66215
Tel.: 800.747.1762 • Fax: 800.487.9915
Canada
50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 800.565.3548 • Fax: 877.747.8116
Fantech reserves the right to modify, at any time and without notice, any or all of its products' features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
Fantech se réserve le droit de modifier partiellement ou entièrement, en tout moment et sans préavis, les
caractéristiques, la conception, les composants et les spécifications de ses produits, afin de conserver sa
position de leader de technologie.
S'il vous plaît visitez notre site siteweb www.fantech.net pour des informations techiques plus détaillées.
Item #: 445421
Rev Date: 2023-03-06
No. d'article #: 445421
Date de révision: 2023-03-06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FIT 70E and is the answer not in the manual?

Questions and answers

Summary of Contents for Fantech FIT 70E

  • Page 1 50 Kanalflakt Way, Bouctouche, NB, E4S 3M5 Tel.: 800.565.3548 • Fax: 877.747.8116 Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position.
  • Page 2: Table Of Contents

    Note Warning/ Information Technical Practical tip Important information note TABLE OF CONTENTS DETERMINING YOUR AIRFLOW REQUIREMENT ............4 INSTALLATION EXAMPLES Fully dedicated system .
  • Page 3: Determining Your Airflow Requirement

    DETERMINING YOUR AIRFLOW REQUIREMENT Installation examples Suggested installation for: Room Count Method • Hydronic baseboard Room classification Number of rooms CFM (L/s) CFM Required • Infloor heating • Electric baseboard Master bedroom x 10 L/s (20 CFM) if yes add 10 L/s (20 CFM) •...
  • Page 4: Partially Dedicated System

    “AIRFLOW BALANCING” procedure found in the section “AIRFLOW BALANCING” * In the case of a multi-zone system, please contact Fantech customer * In the case of a multi-zone system, please contact Fantech customer service prior to installing any installation type requiring the use of the service prior to installing any installation type requiring the use of the furnace interlock"...
  • Page 5: Exterior Ducting Installation

    EXTERIOR DUCTING INSTALLATION Interior ducting installation WEATHERHOOD LOCATION • To maximize airflow through the ductwork system, all ducts should be kept short and have as few bends or elbows as possible. OUTSIDE CORNER INSIDE CORNER • Decide where your intake and exhaust hoods will be located. 36"...
  • Page 6: Faa Installation

    FAA installation Mounting CEILING INSTALLATION LOCATION The FAA must be located in a conditioned space where it will be possible to conveniently service the unit. Typically the FAA would be located in the mechanical room or an area close to the outside wall where the weatherhoods will be mounted.
  • Page 7: Airflow Adjustment & Balancing

    Mounting Airflow adjustment & balancing WALL INSTALLATION BALANCING THE AIRFLOWS IS CRUCIAL TO ENSURE OPTIMAL OPERATION OF THE UNIT. IF THE AIRFLOW IS NOT PROPERLY BALANCED, THE FOLLOWING ISSUES MAY OCCUR: • SIGNIFICANT POSITIVE OR NEGATIVE PRESSURE INSIDE THE HOUSE •...
  • Page 8: Wall Controls

    Measuring the airflow using station (grid) method WALL CONTROLS * Please see instruction manuals for individual controls for proper wiring and set up of control systems. 1. Ensure that unit is not plugged when connecting the control 2. Recirculation mode is only available with the Flex100H ES, HERO series and the models with the “R” suffix at the end of the model number.
  • Page 9: Wiring Diagram

    Wiring diagram WALL CONTROLS (CONT'D) EDF SERIES FEATURES CONNECTS TO EDF8 • MODE button provides 3 modes of operations: Ventilation , Recirculation and Standby • User selected fan speed: Reduced, Medium, Normal and 20 minutes per hour • AUTO setting allows the homeowner to deactivate the dehumidistat •...
  • Page 10: Troubleshooting

    Wiring diagram Troubleshooting (CONT'D) Problem Causes Solutions WIRING DIAGRAM TO Standard Accessory Control Contact Air is too dry Dehumidistat control is set too low Increase the desired level of humidity. Change ventilation mode from Standard Furnace Interlock Wiring continuous mode to standby. FURNACE FAA out of balance Have contractor balance FAA airflows...
  • Page 11: Faa Core Washing Instructions

    Make a scan of the QR code above to access Scannez le code QR ci-dessus pour accéder à Fantech’s warranty in English, French, or la garantie de Fantech en anglais, français ou espagnol. Garantie limitée du Moteur 7 ans, Spanish. Includes a 7y Motor, 5y on Electri- composants électriques et noyau 5 ans inclue.
  • Page 12 Votre système de ventilation doit être installé en conformité avec le code du bâtiment local qui est en vigueur, en l’absence de telles exigences, il est recommandé de vérifier auprès des autorités locales ayant juridiction dans Fantech se réserve le droit de modifier partiellement ou entièrement, en tout moment et sans préavis, les votre région avant d’installer ce produit.
  • Page 13 DÉTERMINER VOS BESOINS DE VENTILATION Méthode compte de pièces Pi 3 /min (L/s) Liste des pièces Nombre de pièces PCM Required x 10 L/s (20 pi 3 /min) Chambre principale 3 /min Si oui, ajoutez 10 L/s (20 pi Sous-sol oui ou no Sinon = 0 x 5 L/s (10 pi 3 /min)
  • Page 14: Exemples D'installation

    * Dans le cas d'un système multi-zone, s'il vous plaît contacter le service à la 1. L’air vicié est aspiré à partir des endroits clés de la maison (salle de bains, clientèle de Fantech avant d'installer tout type d'installation nécessitant l'utilisation cuisine, buanderie).
  • Page 15: Installation Simplifiée

    * Dans le cas d'un système multi-zone, s'il vous plaît contacter le service à la • Ne doit jamais être située dans un garage, un atelier ou un espace non chauffé. clientèle de Fantech avant d'installer tout type d'installation nécessitant l'utilisation synchronisé de la fournaise "...
  • Page 16: Installation Des Conduits Intérieurs

    Installation des conduits intérieurs Installation du AAF EMPLACEMENT • Pour maximiser le débit d’air dans le réseau de conduits, assurez-vous que tous les conduits sont le plus court et le plus droit possible. Le AAF doit être situé dans un endroit chauffé où il sera possible d’en effectuer l'entretient convenablement. Généralement, le AAF doit être situé...
  • Page 17: Installation Au Plafond

    Montage Montage INSTALLATION AU PLAFOND INSTALLATION MURALE 1 À l'aide de la vis avec rondelle, montez le support de montage à 2 À l'aide de la vis avec rondelle, montez les supports au bas de l'unité. 1 À l'aide de la vis avec rondelle, montez le support de montage à 2 À...
  • Page 18: Équilibrage Du Débit D'air

    Équilibrage du débit d'air Mesure du flot d'air en utilisant la méthode du poste de mesure des débits SI LES FLUX D’AIR DE L’APPAREIL NE SONT PAS CORRECTEMENT ÉQUILIBRÉS… • L’EFFICACITÉ DE L’APPAREIL PEUT ÊTRE RÉDUITE. • DES DOMMAGES AU NOYAU DE RÉTABLISSEMENT DE LA CHALEUR PEUVENT SURVENIR. •...
  • Page 19: Commandes Murales

    COMMANDES MURALES COMMANDES MURALES (SUITE) * Veuillez consulter les manuels d’instructions des dispositifs de commande individuels pour connaître la bonne configuration de câblage et l’installation adéquate des systèmes de commande. SÉRIE EDF CARACTÉRISTIQUES RELIER À EDF8 • BOUTON DE SÉLECTION offrant 3 modes de fonctionnement : ventilation, recirculation et attente. 1.
  • Page 20: Schémas Électriques

    Schémas électroniques Schémas électroniques (SUITE) CONNEXION ÉLECTRIQUE Câblage standard de synchronisation avec une fournaise Standard Furnace Interlock Wiring À UNE FOURNAISE BORNES DU THERMOSTAT TERMINALS TERMINALS FOUR QUATRE FILS WIRE DEUX FILS TWO WIRE chauffage seulement heating only DANS LE CAS D'UNE FOURNAISE RACCORDÉE À...
  • Page 21: Dépannage

    Dépannage Instructions de nettoyage des filtres et du noyau récupérateur d'énergie Pour un bon entretien de vos filtres et de votre noyau de récupération d'énergie suivez ces instructions Problème Causes Solutions L’air est trop sec – Le déshumidistat est réglé trop bas –...
  • Page 22: Tableau D'entretien Du Aaf

    Kit, Chain 404261 Kit, Wall Bracket 445488 Scannez le code QR ci-dessus pour accéder à la garantie de Fantech en anglais, français ou Filter, MERV6, 70 cfm, Repl. Kit 414644 espagnol. Garantie limitée du Moteur 7 ans, Manual, Installation 445421 composants électriques et noyau 5 ans inclue.
  • Page 23 Fantech reserves the right to make technical changes. Fantech se réserve le droit de faire des changements tech- For updated documentation please refer to www.fantech.net niques. Pour de la documentation à jour, s'il vous plaît se référer au www.fantech.net Fantech®...