FCC PART 15, SUBPART C, SEC. 15.247 - DIRECT SEQUENCE SPREAD SPECTRUM TRANSMITTERS
PCMCIA Wireless LAN Card, Model WL-211F
6.5.
AC POWERLINE CONDUCTED EMISSIONS @ FCC PART 15, SUBPART B,
PARA.15.107(A)
6.5.1.
Limits
The equipment shall meet the limits of the following table:
Test Frequency Range
0.45 to 30 MHz
6.5.2.
Method of Measurements
Refer to Exhibit 8, Sec. 8.2 of this test report & ANSI C63.4:1992
6.5.3.
Test Arrangement
The following drawing shows details of the test setup for emission measurements.
ULTRATECH GROUP OF LABS
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vhk.ultratech@sympatico.ca, Website: http://www.ultratech-labs.com
•
Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia)
•
Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA)
•
Recognized/Listed by FCC (USA )
•
All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)
Test Limits
EMI Detector Used
µ
Quasi-Peak (Narrow band)
48 dB
V
µ
Quasi-Peak (Broad band)
61 dB
V
FCC ID: MXF-WL211F
Measuring Bandwidth
B = 10 kHz
B = 10 kHz
File #: GTT-013FTX
March 17, 2000
Page 13