Exhibit 5. Summary Of Test Results; Location Of Tests; Applicability & Summary Of Emc Emission Test Results; Modifications Incorporated In The Eut For Compliance Purposes - Gemtek WL-211F Manual

Wireless lan pc card
Table of Contents

Advertisement

FCC PART 15, SUBPART C, SEC. 15.247 - DIRECT SEQUENCE SPREAD SPECTRUM TRANSMITTERS
PCMCIA Wireless LAN Card, Model WL-211F
EXHIBIT 5.
SUMMARY OF TEST RESULTS
5.1.

LOCATION OF TESTS

All of the measurements described in this report were performed at Ultratech Group of Labs located in the city of
Oakville, Province of Ontario, Canada.
AC Powerline Conducted Emissions were performed in UltraTech's shielded room, 16'(L) by 12'(W) by 12'(H).
Radiated Emissions were performed at the Ultratech's 3 Meter Open Field Test Site (OFTS) situated in the Town of
Oakville, province of Ontario.
The above sites have been calibrated in accordance with ANSI C63.4, and found to be in compliance with the
requirements of Sec. 2.948 of the FCC Rules. The descriptions and site measurement data of the Oakville Open Field
Test Site has been filed with FCC office (FCC File No.: 31040/SIT 1300B3) and Industry Canada office (Industry
Canada File No.: IC2049). Last Date of Site Calibration: Sep. 20, 1999.
5.2.
APPLICABILITY & SUMMARY OF EMC EMISSION TEST RESULTS
FCC
PARAGRAPH.
15.107, 15.109
15.247(a)(2)
15.247(b) & 1.1310
15.247(c)
15.247(c), 15.209 &
15.205
15.247(d)
15.247(e)
Note 1:
The digital circuits portion of the EUT has been tested and verified to comply with FCC Part 15, Subpart B,
Class B Digital Devices and Radio Receivers. The engineering test report can be provided upon FCC
requests.
5.3.

MODIFICATIONS INCORPORATED IN THE EUT FOR COMPLIANCE PURPOSES

None
ULTRATECH GROUP OF LABS
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vhk.ultratech@sympatico.ca, Website: http://www.ultratech-labs.com
Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia)
Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA)
Recognized/Listed by FCC (USA )
All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)
TEST REQUIREMENTS
AC Power Conducted Emissions & Radiated Emissions for
Receiver and Digital Circuit Portions
Spectrum Bandwidth of a Direct Sequence Spread Spectrum
System
Maximum Peak Power and RF Exposure Limits
RF Conducted Spurious Emissions at the Transmitter Antenna
Terminal
Transmitter Radiated Emissions
Transmitted Power Density of a Direct Sequence Spread Spectrum
System
Processing Gain of Direct Sequence Spread Spectrum System
Page 11
FCC ID: MXF-WL211F
COMPLIANCE
(YES/NO)
Yes (Note 1)
Yes
Yes
Yes
Yes
Yes
Yes
File #: GTT-013FTX