Oceanic Datamask Quick Start Manual
Oceanic Datamask Quick Start Manual

Oceanic Datamask Quick Start Manual

Dive computer
Hide thumbs Also See for Datamask:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Oceanic Datamask

  • Page 3 Oceanic DataMask. • Prior to diving with the DataMask, you must also read and understand both the Operating Manual and the Oceanic Dive Computer Safety and Reference Manual which provide detailed operating...
  • Page 4 ACTIVATION ACTIVATION • To Manually Activate the DataMask, momentarily press and release the Advance (TOP) Button. • When manually activated, the unit will enter Diagnostic Mode, displaying all segments of the LCD as 8's, followed by dashes (- -), then a countdown from 9 to 0.
  • Page 5 ACTIVATION ACTIVATION • The DataMask will also automatically activate by Wet Contact (only if Wet Activation is set ON). • If no dive is made within 2 hours after initial activation, the unit will automatically deactivate.
  • Page 6: Control Buttons

    CONTROL BUTTONS CONTROL BUTTONS Advance <A-TOP> • The Control Buttons allow you to select display options and access specific information when you want to see it – both on the surface and underwater. • They are also used to enter personal settings and control the Backlight.
  • Page 7 DataMask DataMask • SURFACE MAIN • Tissue Loading Bar Graph • Surface Interval • Pressure • Operating Mode/Elevation • Hold <A-TOP> button: Change Mode. Press <A-TOP> to confirm. • Press <A-TOP> button 3X: Activate Receiver > Transmitter Battery Check •...
  • Page 8 DataMask DataMask • SURF ALT 1 • O2 Bar Graph • FO2 Set Point • Bypass if not set for Nitrox • 5 second return to main • Press <A-TOP> button: Alternate Display 2...
  • Page 9 DataMask DataMask • SURF ALT 2 • Time of Day • Temperature • 5 second return to main • Press <A-TOP> button: Plan Lead-In...
  • Page 10 DataMask DataMask • PLAN LEAD IN • FO2 Set Point • Bypass if not set for Nitrox • 5 second return to main • Press <S-SIDE> button: Pre-Dive Planning Sequence (PDPS™) • Press <A-TOP> button: Fly Time...
  • Page 11 DataMask DataMask • PLAN MODE – PDPS™ • Maximum Operating Depth (if set for Nitrox) • PO2 Set Point • Plan Depth • No-Deco Limit • Press <S-SIDE> button: Step through to 190 ft/57m then back to Surface Main •...
  • Page 12 DataMask DataMask • FLY TIME • 23:50 to 0:00 Countdown Timer • Press <A-TOP> button: DSAT Time...
  • Page 13 DataMask DataMask • DESAT TIME • Calculated Desaturation Time • Press <A-TOP> button: Log Preview...
  • Page 14 DataMask DataMask • LOG PREVIEW • Dive Number • Dive Date • Dive Start Time of Day • Hold <S-SIDE> button: Scroll through previous Log Preview Displays • Press <S-SIDE> button: Log 1 • Press <A-TOP> button: History...
  • Page 15 DataMask DataMask • LOG 1 • Dive Number • Surface Interval • Temperature • Mode ID: No-Deco, Deco, Gauge, or Violation • Press <S-SIDE> button: Log 2 • Press <A-TOP> button: Surface Main...
  • Page 16 DataMask DataMask • LOG 2 • Dive Number • Tissue Loading Bar Graph • Max Depth • Elapsed Dive Time • Press <S-SIDE> button: Log 3 • Press <A-TOP> button: Surface Main...
  • Page 17 DataMask DataMask • LOG 3 • O2 Bar Graph • Max PO2 • FO2 Set Point • Press <S-SIDE> button: Next Log Preview • Press <A-TOP> button: Surface Main...
  • Page 18 DataMask DataMask • HISTORY 1 • Total Dives • Total Dive Hours • Press <S-SIDE> button: History 2 • Press <A-TOP> button: Surface Main...
  • Page 19 DataMask DataMask • HISTORY 2 • Maximum Depth • Max Elevation Level • Minimum Temperature • Press <S-SIDE> button: Surface Main • Press <A-TOP> button: Surface Main...
  • Page 20: Set Mode

    SET MODE SET MODE • After gaining access to Set Mode, settings may be made in sequence one after the other, or you may access a specific item that you want to set, bypassing others. • If the button is not pressed during a 2 minute period while in the Set Mode, the unit will revert to Surface Mode Main.
  • Page 21 SET MODE ACCESS & LOGIC SET MODE ACCESS & LOGIC • To access Set Mode while in Surface Mode Main, depress and hold the <S-SIDE> button for 2 seconds. • Upon entry into Set Mode, the Set G (GLO) menu screen will be displayed.
  • Page 22 DataMask DataMask • SET MODE • Accessed from Surface Main • Hold <S-SIDE> button: Enter Set Mode top-level menu (SET G)
  • Page 23 DataMask DataMask • SET G – GLOW • Hold <S-SIDE> button: Set F – FO2 • Press <A-TOP> button: Set Backlight Level...
  • Page 24: Set Backlight Level

    DataMask DataMask • SET BACKLIGHT LEVEL • Press <S-SIDE> button: Scroll through settings • Press <A-TOP> button: Return to SET G top level menu...
  • Page 25 DataMask DataMask • SET F – FO2 • Hold <S-SIDE> button: Set A - ALARMS • Press <A-TOP> button: Set...
  • Page 26 DataMask DataMask • SET FO2 – AIR • Press <S-SIDE> button: Set FO2 > Air/21-50% • Press <A-TOP> button: Set FO2 Default...
  • Page 27 DataMask DataMask • SET FO2 – NITROX • FO2 Set Point • PO2 Set Point • Max Operating Depth • Press <S-SIDE> button: Set FO2 > Air/21-50% • Press <A-TOP> button: Set FO2 50% Default...
  • Page 28 DataMask DataMask • SET FO2 50% DEFAULT • Press <S-SIDE> button: Toggle ON and OFF • Press <A-TOP> button: Set F - FO2...
  • Page 29 DataMask DataMask • SET A – ALARMS • Hold <S-SIDE> button: Set U - UTILITIES • Press <A-TOP> button: Set Audible Alarm...
  • Page 30 DataMask DataMask • SET AUDIBLE ALARM • Press <S-SIDE> button: Toggle ON and OFF • Press <A-TOP> button: Set Max Depth Alarm...
  • Page 31 DataMask DataMask • SET SCUBA MAX DEPTH ALARM • Press <S-SIDE> button: Scroll 30 - 330 ft / 10 - 100m • Press <A-TOP> button: Set Elapsed Dive Time Alarm...
  • Page 32 DataMask DataMask • SET ELAPSED DIVE TIME ALARM • Press <S-SIDE> button: Scroll :10 - 3:00 • Press <A-TOP> button: Set Tissue Loading Bar Graph Alarm...
  • Page 33 DataMask DataMask • SET TISSUE LOADING BAR GRAPH ALARM • Press <S-SIDE> button: Scroll 5 – 1 segments • Press <A-TOP> button: Set Dive Time Remaining Alarm...
  • Page 34 DataMask DataMask • SET DIVE TIME REMAINING ALARM • Press <S-SIDE> button: Scroll :00 - :20 • Press <A-TOP> button: Set Turn Pressure Alarm...
  • Page 35: Set Turn Pressure Alarm

    DataMask DataMask • SET TURN PRESSURE ALARM • Press <S-SIDE> button: Scroll OFF, 1000 – 3000 psi / 70 – 205 BAR • Press <A-TOP> button: Set End Pressure Alarm...
  • Page 36: Set End Pressure Alarm

    DataMask DataMask • SET END PRESSURE ALARM • Press <S-SIDE> button: Scorll 300 – 1500 psi / 20 – 105 BAR • Press <A-TOP> button: Set Max PO2 Alarm...
  • Page 37 DataMask DataMask • SET PO2 ALARM • Press <S-SIDE> button: Scroll 1.20 – 1.60 ATA • Press <A-TOP> button: Set A - ALARMS...
  • Page 38 DataMask DataMask • SET U – UTILITIES • Hold <S-SIDE> button: Set T - TIME • Press <A-TOP> button: Set Wet Activation...
  • Page 39 DataMask DataMask • SET WATER ACTIVATION • Press <S-SIDE> button: Toggle ON and OFF • Press <A-TOP> button: Set Units...
  • Page 40 DataMask DataMask • SET UNITS • Press <S-SIDE> button: Toggle Imperial and Metric • Press <A-TOP> button: Set Safety Stop Depth and Time...
  • Page 41 DataMask DataMask • SET SAFETY STOP – DEPTH AND TIME • Press <S-SIDE> button: Toggle OFF/3/5 minutes • Press <A-TOP> button: Accept time • Press <S-SIDE> button: Toggle 10/15/20 feet 3/4/5/6m • Press <A-TOP> button: Set Conservative Factor...
  • Page 42: Set Conservative Factor

    DataMask DataMask • SET CONSERVATIVE FACTOR • Press <S-SIDE> button: Toggle ON and OFF • Press <A-TOP> button: Set Sampling Rate...
  • Page 43 DataMask DataMask • SET SAMPLING RATE (PC DOWNLOAD) • Press <S-SIDE> button: Toggle 2/15/30/60 seconds • Press <A-TOP> button: Set Transmitter Link Code...
  • Page 44 DataMask DataMask • SET LINK CODE • Press <S-SIDE> button: Scroll ON/OFF, 1 - 99999 • Press <A-TOP> button: Set U - UTILITIES...
  • Page 45 DataMask DataMask • SET T – TIME • Hold <S-SIDE> button: Mask ID • Press <A-TOP> button: Set Hour Format...
  • Page 46: Set Hour Format

    DataMask DataMask • SET HOUR FORMAT • Press <S-SIDE> button: Toggle 12 and 24 • Press <A-TOP> button: Set Time...
  • Page 47 DataMask DataMask • SET TIME • Press <S-SIDE> button: Set Hour • Press <A-TOP> button: Accept Hour • Press <S-SIDE> button: Set Minutes • Press <A-TOP> button: Set Date...
  • Page 48 DataMask DataMask • SET DATE • Press <S-SIDE> button: Set Year • Press <A-TOP> button: Accept Year • Press <S-SIDE> button: Set Month • Press <A-TOP> button: Accept Month • Press <S-SIDE> button: Set • Press <A-TOP> button: Set T - Time...
  • Page 49 DataMask DataMask • MASK ID • Mask Firmware Revision • Mask Serial Number • Hold <S-SIDE> button: Surface Main...
  • Page 50 Diving with the DataMask Diving with the DataMask...
  • Page 51: Control Of Displays

    CONTROL OF DISPLAYS CONTROL OF DISPLAYS • During the dive, various displays of information are available. The screens may be accessed as often as desired by pressing and releasing the Advance (top) button momentarily (< 2 seconds). If the Advance button is not pressed again to access the next available screen, the display will revert to the Main Dive Mode Display after 5 seconds.
  • Page 52 DataMask DataMask • NORM DIVE – MAIN • Current Depth • Pressure • Dive Time Remaining • Tissue Loading Bar Graph • Air Time <if secondary> • Press <A-TOP> button: Alternate Display 1 • Press <S-SIDE> button: Toggle Backlight ON and •...
  • Page 53 DataMask DataMask • NORM DIVE ALTERNATE 1 • Max Depth • Elapsed Dive Time • Air Time/NDC Remaining • Press <A-TOP> button: Alternate Display 2 • 5 second return to main...
  • Page 54 DataMask DataMask • NORM DIVE ALTERNATE 2 • • FO2 Set Point • O2 Bar Graph • Press <A-TOP> button: Alternate Display 3 • 5 second return to main...
  • Page 55 DataMask DataMask • NORM DIVE ALTERNATE 3 • Time of Day • Temperature • Press <A-TOP> button: Norm Dive Main • 5 second return to main...
  • Page 56: Safety Stop

    DataMask DataMask • SAFETY STOP • Current Depth • Pressure • STOP Icon • Stop Depth • Countdown Timer • Tissue Loading Bar Graph...
  • Page 57: No - Deco Safety Stop

    DECO SAFETY STOP DECO SAFETY STOP • The Safety Stop will be displayed until the countdown times out, or another descent is made below 30 FT (10 M), or the diver surfaces. • There is no Penalty for surfacing prior to completing the Safety Stop.
  • Page 58: Deco Stop - Main

    DataMask DataMask • DECO STOP – MAIN • Current Depth • Pressure • STOP Icon with Ceiling Indicator Arrows • Stop Depth • Countdown Timer • Tissue Loading Bar Graph...
  • Page 59 DataMask DataMask • DECO STOP – ALTERNATE 1 • Max Depth • Elapsed Dive Time • Air Time Remaining • Total Ascent Time...
  • Page 60 DataMask DataMask • ASCENT ALARM • SLO Graphic alternates with Pressure...
  • Page 61 DataMask DataMask • GAUGE MODE - MAIN • Current Depth • Pressure <EDT> • Air Time Remaining • GAU Graphic • Press <A-TOP> button: Alternate Display 1 • Press <S-SIDE> button: Toggle Backlight ON and OFF • Hold <S-SIDE> button: Set GLO Level >...
  • Page 62 DataMask DataMask • GAUGE DIVE ALTERNATE 1 • Max Depth • EDT <Pressure> • Air Time Remaining • Press <A-TOP> button: Alternate Display 2 • 5 second return to main...
  • Page 63 We hope that you have found this QuickStart Guide helpful. We encourage you to visit our web site and read the Operating Manual to learn about the many other features that the Oceanic DataMask has to offer – we are quite sure that you won’t be disappointed.

Table of Contents