2-1: Measurement mode of the load of JOG dial
A
This mode is to measure the load of JOG dial. When the measurement mode starts, FX1 ON of the left DECK will light up.
When the JOG dial is rotated swiftly, measurement for the top speed and the time required for slowdown will begin.
When the rotation speed of the Jog dial exceeds 7 times normal speed, the time required for slowdown will be assessed
whether it is in the range or not. The result will be displayed on LED.
Top speed
Time required for slowdown
Operation procedures
1. Spin the Jog dial swiftly.
To start measurement, the maximum Jog rotation speed must be 7 times normal speed or higher.
If the maximum speed does not reach 7.0 times normal speed, PAD LEDs (8 PADs)will blink several times.
2. The number of sessions will be displayed up to four sessions on LED as follows.
B
The end of 1st session
The end of 2nd session
The end of 3rd session
The end of 4th session
After the end of 4th session
3. The result will be displayed on LED.
OK
NG (failed)
4. When the measurement is failed, PAD LED indicates as follows.
NG (Heavy)
NG (Light)
C
The number of measurement sessions executed is displayed up to 4 sessions.
The measurement can be continued 5 sessions and more, however the number of sessions will not be displayed.
When the session ended, an average is taken each time and the result will be displayed on LED.
Regulation value is 100
[AUTO] LED is turned on if the measurement is OK
[TAP] LED is turned on if the measurement is failed.
D
Indicates the number of measurement
sessions executed (up to 4 sessions).
E
If the maximum speed does not reach 7.0 times normal speed,
the all PAD LEDs of the rotated side will blink.
NG(Heavy)
NG(Light)
The measurement result
You can check the measurement result using "JOG_Checker.exe".
F
32
1
2
: when normal speed is defined as one rotation in 1.8 sec
: Time required for the jog dial to decrease its rotation speed
HOT CUE lighting
PAD FX1 lighting
SLICER lighting
SAMPLER lighting
remain unchaged
[AUTO] LED is turned on
[TAP] LED is turned on.
PAD[5] lightin
PAD[8] lighting
40 [msec]. (The specification is subject to change.)
[AUTO] LED is turned on if the measurement is OK
[TAP] LED is turned on if the measurement is failed.
If the maximum speed does not reach 7.0 times normal speed,
the all PAD LEDs of the rotated side will blink.
2
3
Indicates the number of measurement
sessions executed (up to 4 sessions).
NG(Heavy)
NG(Light)