Sensor Handling - Honeywell CRIR-E1 User Manual

Commercial carbon dioxide sensor

Advertisement

CAUTION
IMPROPER SENSOR HANDLING
• The CRIR E1 is an electrostatic-sensitive
device (ESD).
• Handle the CRIR E1 using appropriate ESD
methods such as electrostatic dissipative
gloves, wrist straps, etc.
• Handle the CRIR E1 by the black PCB on the
edges as shown in Figure 1.
• Ensure that the gas diffusion area shown in
Figure 1 is not blocked or contaminated.
• Ensure that force is not applied to the CRIR
E1's optical chamber,
• Ensure that the CRIR E1 is not subject to
drops and vibration.
Failure to comply with these instructions may
result in product damage.
Tel: 07788 548013
solentgasconsultants@gmail.com
Honeywell CRIR-E1 User Guide

SENSOR HANDLING

Figure 3 - CRIR E1 Appearance
CAUTION
EXPOSURE TO HARMFUL GASES
Ensure that the CRIR E1 does not come into
contact with the following harmful gases:
• Acidic: Includes HCl, HF, H2S, SO
• Basic: Includes NH
• Strong oxidizing: Includes Cl
etc.
Failure to comply with these instructions may
result in product damage.
NOTICE
To extend the CRIR E1's lifetime, ensure that it
does not come into contact with salt spray, oil
mist, soot, and high humidity.
, NOx, etc.
2
, PH
, N
H
, etc.
3
3
2
4
, F
, O
, H
O
2
2
3
2
2
,