TROUBLESHOOTING – MOTOR
Before attempting to troubleshoot the Motor, make sure an adequate
power source is available. The unit batteries should be fully charged or
the unit should be plugged into to A/C service with batteries installed.
Do not attempt to troubleshoot the Motor without assuring a full 12V DC
charge
The following tests require only a DC voltmeter (or DC test light) and a
jumper lead.
Step 1 - Attach voltmeter (or test light) leads to the negative and positive
switch terminals on back of wall switch (See Fig. 10). Does the meter
indicate 12V DC?
If YES, see Step 2; if NO see Step 3.
Step 2 - If YES, at the motor, check the incoming leads to 12V DC (if
necessary, disconnect leads at wire splices). Does meter indicate 12V
DC? If YES, Motor needs to be replaced. The motor is not field
serviceable. DO NOT ATTEMPT TO REPAIR. If NO, Inspect all wires
and connections between the wall switch and the motor. Repair
connections as necessary. Recheck as in Step 1.
Step 3 - If NO, Inspect all connections between battery and switch.
Inspect 30A Auto-reset Circuit Breaker (See Fig. 10 for location).
Recheck as above in Step 1.
Since there are no field serviceable parts in the motor, electrical
troubleshooting and service is limited to replacing only those
components as previously outlined.
Thorough inspection of wiring and connections is the only other electrical
service that can be performed.