Digital Access Keypad Manual
INSTALLER PROGRAMMING
These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.
Enter Programming Mode
Enter Master code
Confirm
*
X X X X
*
*Key in the Master Code.
Note: For first-time use, Master code is
0 0 0 0
Data Refresh
Option
Confirm
Function
Clears all previously stored data.
8 9 0 1
#
Configure Relay Outputs
Option Output time
Function
Confirm
1 to 999
Relay momentary mode, from 1 to 999 seconds
4 0
#
Relay shunt mode (ON/OFF)
4 1
#
Relay Output Inhibit Control (lockout mode)
Option Code Entry
Confirm
Function
1 to 999
Lockout for 1 to 999 seconds
5 0
#
Lockout shunt mode (ON/OFF)
5 1
#
Wrong Code Lockout
Option
Function
# of tries
Confirm
After 10 successive wrong codes, 30-second lockout
7 0
After 10 successive wrong codes, Duress activated
7 1
5 to 10
After 5 to 10 wrong codes, 15-min. lockout - Can reset with Master Code
7 2
#
None of the above
7 6 0 0
#
Output Activation Announcer
Option Code entry
Confirm
Function
{
1
1-sec. beep notifies the user to open the door when the output relay is activated with the
#
user code or egress button. Use with a locking device which gives no sound when it
8 1
activates, such as a magnetic lock.
0
#
The beep is disabled, replaced by 2 short beeps for valid user codes.
User Code Entry Mode
Option Code entry
Confirm
Function
{
1
Auto Entry Mode is selected. The
#
code entry. The User Codes MUST be set to the same digit length as the Master Code,
8 2
from 4-8 digits.
0
Manual Entry Mode is selected. The
#
code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length.
Keypress Beeps
Option Code entry
Confirm
Function
{
1
Keypad beeps when a key is pressed.
#
8 3
0
Silent operation -- keypad does not beep when a key is pressed.
#
Exit Programming Mode
Confirm
Function
Exits programming mode, returns keypad to normal operations
*
USER CODE WORKSHEET
To print out a blank worksheet where all user codes
can be recorded, please visit www.seco-larm.com
and select the Model #, "SK-1011-SQ" in the drop
down menu for the burglar section. On the product
page click on "User Code Worksheet," which will
load the .PDF.
Page 6
(DEFAULT:
Function
Enter into programming mode
(DEFAULT: Momentary, 1-sec. output)
(DEFAULT: Momentary, 1-sec. output)
(DEFAULT: 10 tries / 30 seconds)
(DEFAULT: Manual)
#
key that follows the user code is NOT required in
#
key that follows the user code is required in
SECO-LARM U.S.A., Inc.
SPECIFICATIONS:
Power:
)
0 0 0 0
• Operation voltage -- 12-24 Volts AC/DC. No jumper needed to set voltage.
• Stand-by current drain -- 10mA @12VDC.
• Active current drain (press keypad key) -- Under 30mA.
• Active current drain (relay activated) -- Under 80mA.
Outputs:
• Relay output -- 5A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second timed output or
shunt (start/stop) output. Three terminals.
• Tamper output -- N.C. output. Connect to tamper circuit of alarm control panel. Two terminals.
Inputs:
• Power -- 12-24Volts AC/DC. Two terminals.
• Egress -- N.O., ground (-). Single terminal.
Code Operation:
• Up to 100 user codes, 10,000 possible user code combinations.
• Max. 10 seconds to enter each digit.
• Max. 30 seconds to enter each code.
Dimensions (keypad with back box):
• 4-5/8" x 2-7/8" x 1-7/8" (117 x 74 x 48 mm).
Weight (keypad with back box):
• 6.3 oz. (180 grams).
(DEFAULT: On)
WIRING (SAMPLE INSTALLATION):
Tamper
N.C.
Connect to the N.C.
24hr. zone of alarm
panel or other
signalling device.
(DEFAULT: On)
Digital Access Keypad Manual
(+) (--)
OUTPUT 1
EG
N.C.
C.
N.O.
12~24V AC/DC
(+)
N.C. N.O.
OR
--
+
Electric
Lock
12VDC
--
+
power
supply
REMARKS:
(for DC
Output relay
Diode
use only)
N.O. output for fail-secure lock.
1N4004
N.C. output for fail-safe lock.
Cathode
Egress button (inside the
N.O.
protected premises)
Additional egress buttons
can be connected in parallel
N.O.
as needed
Page 3