OPERATING PARAMETERS:
Water Pressure (rnln-rnax) 15 psi- I(30 psl
103 kPa - 690 kPa
Temperature
(mln-max)
40°F - 100°F
4°C - 38°C
pH
6,5 - 8,5
6,5 - 8.5
Iron
0 ppm - 0.3 ppm
0 rngL - 0.3 rngL
Manganese
0 ppm - 0.05 ppm
0 mgL - 0,05 mgL
Hydrogen
Sulfide
None
None
Turbidity
Less than 5 NTU
Less than 5 NTU
Bacteria _
Must be potable
Must be potable
PLEASENOTE:
This System contains a replaceable
Filter, model number RCCWF, which must be
replaced
at regular Intervals to maintain
proper performance.
Use only factory
approved
filters. For parts or service, please contact the outlet where your unit was
purchased
or contact
EeoWater at 1-800-86WATER (1-800-869-2837) or at the address
below.
qhe _CCWF
C_rt_Ige
does not flite¢ or _JHbocterla
_
vl_e_
do not _e
thl_ _y3tem wlth water that
i_ mlcr o blolOglcally
uns_:;fe or with water of unknov_n quality wlthou t adequate
_nfectlon
before
or ati_" the _ystem.
Thls ddnklng water
system conforms to ANSI/NSF Std, 53 for Lead and Turbldity reduction
and ANSIINSF Std 42
for Chlorine (Class I) and Taste ar_l Odor €eduction
as verlfled
and substantfate_
by test data, Fo_ conditions
of use, health
claims certified
by the Cotlfornla
Department
or Health Services, and replacement
parts, see
product
data
sheet. Cartfc_nla Dept. of Health Certlflcate
Number
97-1311
Caution:
Do net use wlth water that I_ microblologlcaily
unsafe or of unknown
quallt¥
without
adequate
disinfection
before
or offer the system.
EcoWater
Systems
PO Box 64420, St. Paul, MN 55164
1-800-869-2837
Page 9
Need help?
Do you have a question about the EcoWater CWF and is the answer not in the manual?
Questions and answers