12. This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conductor
cord and 3-prong, grounding-type plug.
Hazardous voltage. Can shock, burn or
cause death. To reduce the risk of electric shock, pull the
plug before servicing. This pump has not been investigated
for use in swimming pool areas. The pump is supplied with
a grounding conductor and grounding-type attachment
plug. Be sure it is connected only to a properly grounded
grounding-type receptacle.
Where a 2-prong wall receptacle is encountered, it must be
replaced with properly grounded 3-prong receptacle
installed in accordance with the codes and ordinances that
apply.
Do not walk on wet area until all power has been
turned off. If the shut-off box is in the basement, call the
electric company or hydro authority to shutoff the service
to house, or call your local fire department for instruc-
tions. Failure to follow this warning can result in a fatal
electrical shock.
Do not lift the pump by the power cord.
13. All wiring should be performed by a qualified
electrician.
14. Make certain the power source conforms to the require-
ments of your equipment.
15. Protect the electrical cord from sharp objects, hot surfaces,
oil, and chemicals. Avoid kinking the cord. Replace or
repair damaged or worn cords immediately.
16. Do not touch an operating motor. Modern motors can
operate at high temperatures.
17. Do not handle the pump or the pump motor, or change
fuses with wet hands or when standing on wet or damp
surface, or in water.

INSTALLATION

1. Set the pump on a hard surface in at least 2 inches of
water.
2. Connect the discharge line with the fittings provided.
3. The pump should not be installed on clay, dirt, mud or
sand surfaces. Although the pump will usually pass small
particles suspended in water, clean the area to be pumped
of small stones and gravel which could clog the pump.
*NOTICE: Grass, mud, sand or pea gravel can clog the pump
and reduce it's performance. Keep the pump inlet screen clean.
4. To reduce motor noise and vibrations when using rigid
pipe, a short length of rubber hose (e.g. radiator hose) can
be connected into the discharge line near the pump using
suitable clamps.
5. Power Supply: This pump is designed for 115 V., 60 Hz.,
operation and requires a minimum 15 amp individual
branch circuit. Pump is supplied with a 3-wire cord with
grounding-type plug.
Hazardous voltage. Can shock, burn or
cause death. Pump should always be electrically ground-
ed to a suitable electrical ground such as a grounded
water pipe or a properly grounded metallic raceway, or
ground wire system. Do not cut off round ground pin.
6. If the pump discharge line is exposed to an outside sub-
freezing atmosphere, the portion of line exposed must be
installed so any water remaining in the pipe will drain to
the outfall by gravity. Failure to do this can cause the
water trapped in the discharge to freeze which could result
in damage to the pump.
7. Check the system operation by observing the pump
operation through one complete cycle.
Risk of flooding. Failure to make this
operational check may lead to improper operation, pre-
mature failure, and flooding.