Flow Sensor Cleaning
1. In a counter-clockwise motion unscrew the collar of the flow sensor (7) and remove it from
the electrolytic cell conduit. See "Part Reference".
2. If deposits and debris are seen on the surface of the flow sensor, then use a garden hose to
wash it off.
Hinge
3. If flushing with water does not remove the deposits, use a plastic brush to clean the surface
and the hinge if necessary. Do not use a metal brush.
4. After the flow sensor has been inspected and cleaned, align the locator notch on the flow
sensor to the connection ridge in the conduit. Now turn the collar in a clockwise motion,
tightening the sensor back into its position. Do not overtighten.
Electrolytic Cell Cleaning
The electrolytic cell has a self cleaning function incorporated into the electronic control's
programming. In most cases this self cleaning action will keep the cell working at optimum
efficiency. If the pool water is hard (high mineral content) the cell may require periodic manual
cleaning. To maintain maximum performance, we recommend that you open and visually inspect
the electrolytic cell monthly.
The following steps provide instructions on how to clean your cell.
Inspection and cleaning:
1. Switch off the unit, unplug the power cord from the electrical socket.
2. For filter pumps with 1-1/2" (38mm) hose size - Turn both plunger valve handles fully
clockwise until they stop. This closes the valve, prevents the water from flowing out of the
pool.
3. Disconnect the 2 hoses from the Ozone & Saltwater System, and attach the cell covers (11)
to the inlet and outlet of the electrolytic cell (9).
SAVE THESE INSTRUCTIONS

MAINTENANCE

Locator Notch
Connection Ridge