• When an extension cable is required, be sure to use a rubber sheathed
flexible cable.
• Limit length of extension cables; 60m for cables of 1.5mm2 and 100m
for cables of 2.5mm2.
• Keep the generator away from other electric cables or wires such as
distribution network.
• The DC receptacle can be used while the AC power is in use. If you use
both at the same time, be sure not to exceed the total power for AC and
DC.
• Most appliance motors require more than their rated wattage for start-up.
AC Application
1. Start the engine and make sure the output indicator light (green)
illuminates.
2. Confirm that the appliance to be used is switched off, and plug in the
appliance.
Substantial overloading that continuously lights the overload indicator
light (red) may damage the generator. Marginal overloading that
temporarily lights the overload indicator light (red) may shorten the
service life of the generator.
Be sure that all appliances are in good working order before connect-
ing them to the generator, if an appliance begins to operate abnormally,
becomes sluggish, or stops suddenly, turn off the generator engine
switch immediately. Then disconnect the appliance, and examine it for
signs of malfunction.
18
operation
Ouput Indicator Light
Overload Indicator Light