Ac Application - BE I2500 Operation Manual

Inverter generator
Table of Contents

Advertisement

• When an extension cable is required, be sure to use a rubber sheathed 
  flexible cable.
• Limit length of extension cables; 60m for cables of 1.5mm2 and 100m 
  for cables of 2.5mm2.
• Keep the generator away from other electric cables or wires such as 
  distribution network.
• The DC receptacle can be used while the AC power is in use. If you use 
  both at the same time, be sure not to exceed the total power for AC and 
  DC.
• Most appliance motors require more than their rated wattage for start-up.

AC Application

1. Start the engine and make sure the output indicator light (green) 
    illuminates.
2. Confirm that the appliance to be used is switched off, and plug in the 
    appliance.                                                                              
Substantial overloading that continuously lights the overload indicator 
light (red) may damage the generator. Marginal overloading that 
temporarily lights the overload indicator light (red) may shorten the 
service life of the generator.
Be sure that all appliances are in good working order before connect-
ing them to the generator, if an appliance begins to operate abnormally, 
becomes sluggish, or stops suddenly, turn off the generator engine 
switch immediately. Then disconnect the appliance, and examine it for 
signs of malfunction. 
18
operation
Ouput Indicator Light
Overload Indicator Light 
NOTICE
NOTICE
**I2500 Image

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I3500

Table of Contents