High Altitude Operation

• At high altitude, the standard carburetor air–fuel mixture will be 
  excessively rich.
• Performance will decrease, and fuel consumption will increase.
• High altitude performance can be improved by installing a smaller 
  diameter main fuel jet in the carburetor and readjusting the slow tempo    
  screws. 
• If you always operate the generator at altitudes higher than 1,500 m   
  (4,000 feet) above sea level, have your dealer perform these carburetor 
  modifications.
• Even with suitable carburetor jetting, engine horsepower will decrease 
  approximately 3.5% for each 300m (1,000 feet) increase in altitude. The   
  effect of altitude on the horsepower will be greater than this if no 
  carburetor modification is made.
Operation of the generator at an altitude lower than the carburetor is 
jetted for may result in reduced performance, overheating, and serious 
engine damage caused by an excessively lean air/fuel mixture.

general Operation

To prevent electrical shock from faulty appliances , the 
generator should be grounded. 
• Connect an electric conductor (cable) of at least 1.5mm2 between the   
  generator's ground terminal and an external ground source.
• Connections for standby power to a building's electrical system must be 
  made by a qualified electrician and must comply with all applicable laws 
  and electrical codes. Improper connections can allow electrical current 
  from the generator to back feed into the utility lines. Such back feed may 
  electrocute utility power is restored; the generator may explode, burn, or 
  cause fires in the building's electrical system.
• Do not exceed the current limit specified for any one receptacle
• Do not connect the generator to a household circuit . This could cause 
  the damage to the generator or to electrical appliances in the house.
• Do not modify or use the generator for other purpose than it is intended 
  for. 
• Do not connect generators in parallel.  
• Do not connect an extension to exhaust pipe.