BE-GX200GEN – BE-GX270GEN – BE-GX390 GEN USER MANUAL Model shown BE-GX390 GEN BEFORE USE YOU MUST READ THIS MANUAL COMPLETELY – RETAIN FOR FUTURE USE Licensed by BE Pressure Supply Inc, Canada...
Record of Identification Numbers Generator If you need to contact your dealer for information or servicing, please provide the product model and identification numbers. You will need to locate the model and serial number for the machine and record the information in the places provided below. Date of Purchase: Dealer Name: Dealer Phone:...
1. SAFETY. 1.1. The operator of the machine; 1.1.1. Is responsible for and has a duty of care in making sure that the machine is operated safely and in accordance with the instructions in this user manual. 1.1.2. Should never leave it in a condition, which would allow an untrained or unauthorised person/s to operate this machine.
Page 5
1.3. Carbon monoxide 1.3.1. Carbon monoxide is a colourless and odourless gas. Breathing it can cause death as well as serious long-term health problems such as brain damage. 1.3.2. The symptoms of carbon monoxide poisoning can include the following; 1.3.2.1. Headaches, Dizziness, Nausea, Breathlessness, Collapsing or Loss of Consciousness.
Page 6
1.4.8.2. The generators are fitted with an RCD, which protects against electric shock hazards. The RCD may not function correctly if the generator is not properly grounded/earthed. All BE Generators have the neutral internally bonded to the ground/earth wires. 1.4.8.3.
Page 7
1.4.10.12. Use only "LISTED" extension leads. When tools or appliances are used/operated outside, use only extension leads marked for “Outdoor Use". Extension leads, when not in use, should be stored in a dry and well-ventilated area. Page 7...
1.4.10.13. Always switch off generator's AC circuit breaker and disconnect tools or appliances when not in use, before servicing, adjusting, or installing accessories and attachments. 1.4.10.14. Stop the engine before starting any maintenance, servicing or repair. 1.4.10.15. Only allow properly trained personnel to maintain/repair the generator. 2.
Connect the other end of the wire securely to a suitable ground/earth point. 3.2. All electrical tools and appliances operated from this generator must be properly grounded/earthed by use of a third wire or be "Double Insulated".
Page 10
4.2. Fuelling. Explosive fuel! Petrol is extremely flammable and its vapours can explode if ignited. Petrol quality deteriorates over time. Periodically replace with fresh fuel every three months or add a fuel stabiliser. 4.2.1. DO NOT refuel while smoking or near open flame or other such potential fire hazards.
5.3. Turn on the fuel valve to ‘ON’ position (bottom lever). 5.4. Move the choke lever to the ‘CLOSED’ position (upper lever). 5.5. Turn the engine switch to ‘ON’. 5.6. Pull the recoil starter handle slowly until passing the compression point (resistance will be felt). Page 11 Ver3...
6.1. To test the RCD receptacle on the unit, apply a test load or lamp to each AC outlet to verify output. Then push the test button. 6.1.1. The reset button should pop out and there should be no power at the receptacle. 6.1.2. If the reset button does not pop out then you MUST NOT continue to use the generator.
8.9. Loads such as submersible pumps and air compressors require a very large force to start. They need 3 to 5 times the normal running wattage in order to start. For example, a 5000- watt generator would only be able to drive a 1000 to 7000 watt pump. 8.10.
10.2. Spark arrester. If the engine has been running, the muffler/exhaust and spark arrester will be very hot. Allow the muffler/exhaust to cool down before cleaning. 10.2.1. YOU MUST clean the spark arrester regularly to keep it functioning as designed.
Page 15
10.5.1.1. Use a brush to remove carbon deposits from the spark arrester screen. Be careful not to damage the screen. 10.5.1.2. The spark arrester MUST BE free of breaks/holes. If damaged replace the spark arrester. 10.5.1.3. Re-fit the spark arrester, and muffler/exhaust cover in reverse order of dis- assembly.
10.6.2. When the engine has stopped automatically, turn off the generator, and check the oil level. 10.6.3. Refill engine oil to the upper level as instructed and restart the engine. 11. MAINTENANCE MAKE SURE the engine has been stopped before starting any maintenance, servicing or repair.
14. DECLARATIONS OF CONFORMITY 14.1. Genpower Ltd confirms that these BE products conform to the following CE Directives; 14.1.1. 2006/42/EC Machinery Directive 14.1.2. 2004/108/EC EMC Directive 14.1.3. 2000/14/EC Noise Emissions Directive 14.1.4. 97/68/EC NRMM Emissions Directive 14.1.5. 2006/95/EC Low Voltage Directive...