Genie DPL-25S Operator's Manual page 14

Hide thumbs Also See for DPL-25S:
Table of Contents

Advertisement

Operator's Manual
MAINTENANCE
Check the Battery - DC Models
Proper battery condition is essential to good
machine performance and safe operation. Improper
fluid levels or damaged cables and connections can
result in component damage and hazardous
conditions.
Electrocution hazard. Contact with
hot or live circuits could result in
death or serious injury. Remove all
rings, watches and other jewelry.
Bodily injury hazard. Batteries
contain acid. Avoid spilling or
contacting battery acid. Neutralize
battery acid spills with baking soda
and water.
Perform this test after fully
charging the batteries.
1 Put on protective clothing and eye wear.
2 Remove the battery vent caps.
3 Check the battery acid level. If needed,
replenish with distilled water to the bottom of the
battery fill tube. Do not overfill.
4 Install the vent caps.
12
Check the Hydraulic Oil Level -
AC and DC Models
Maintaining the hydraulic oil at the proper level is
essential to machine operation. Improper hydraulic
oil levels can damage hydraulic components. Daily
checks allow the inspector to identify changes in oil
level that might indicate the presence of hydraulic
system problems.
1 Be sure the platform is fully lowered.
2 Check the sight gauge on the side of the
hydraulic reservoir.
Result: The hydraulic oil level should be visible
in the middle of the sight gauge. Do not overfill.
Hydraulic oil specifications
Hydraulic oil type
Genie DPL Super Series
Second Edition • First Printing
Chevron Rykon
Premium MV equivalent
Part No. 82799

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpl-30sDpl-35s

Table of Contents