CM-150 CA fuse types
Control module
Fuse type
CM-150 CA, 24V
4 A, 250 V
CM-150 CA, 7.5/12V
5 A, 250 V
Two replacement fuses are included
E
in the box with the CM-150 CA,
Surface Mount.
Two replacement fuses are located
E
inside the housing of the CM-150 CA,
DIN Rail Mount.

Replacing Fuses

CM-150 CA has two fuses, each of which protects a Flex strand from
excessive current. Two extra fuses are included in with all DIN rail mountable
CM-150 CA devices.
Surface Mount Fuse Replacement
1.
Make sure that the device power is OFF.
2.
Using a Phillips screwdriver, unscrew the six screws holding the cover in place.
Remove the device cover.
3.
Pull the protective cover from the fuse you wish to replace.
4.
Remove the fuse from its metal clips.
5.
Replace with a new fuse of the same type, as noted in the margin.
6.
Replace the protective cover over the fuse and clips.
7.
Replace the device cover and secure it with the six cover screws.
DIN Rail Mount Fuse Replacement
1.
Make sure that the device power is OFF.
2.
Open the device cover.
3.
Remove the fuse from its metal clips.
Replacement fuses
4.
Replace with a new fuse of the same type, as noted in the margin.
5.
Close the device cover.
19