#2 H-CAN
Important Note! For a limited number of modules like the C8315 it is possible to communicate with a
CAN bus speed of 1MBit/s. This provides more bandwidth to move measuring data from the module via
the frame controller to the J*AM based loudness logger. Be sure that all modules within a frame are
operating with the same CAN bus speed.
#3 BOOT
#4 ID +16
#5 MASTER
#6 DANTE
#7 1 : 1
#8
INIT
C8000
64ch BNC MADI & AoIP I/O
OFF = CAN bus speed 256kBit/s
ON
= CAN bus speed 1Mbit/s
OFF = Internal use and must be set to OFF.
OFF = CAN bus address range is standard (counting from 0x0 to 0xF)
see rotary encoder settings above.
ON
= CAN bus address range is extended by +16
(counting from 0x10 to 0x1F).
OFF = Sync is taken from the c8k frame
ON
= The C8315 will be sync master of the frame (or an C8934 island).
Sync source is defined by SW2 #6
OFF = MADI is sync reference.
ON
= DANTE is sync reference.
OFF = Remote controlled operation by C8702 frame controller.
ON
= Stand alone operation. MADI and AS67 interfaces are bridged.
OFF = Internal use and must be set to OFF.
Pressing the INIT button during power up will initialize the module
parameters to factory default values.