installation

Initial set up
ADDRESS
ADDRESS:
SW2:
#1 BUS-EN
Important note! Since this type of module has an electronic output routing facility, great care must be
taken when installing or exchanging a module when such frame has components which are On Air!
If an unknown output bus configuration is stored, it can cause a conflict with other modules in the frame.
If you are not sure about the output bus configuration you must turn BUS-EN=OFF before inserting such a
module into a system that is On Air. If all settings are done remotely and the unit fits into the bus
assignment scheme of that frame, you must remove it and place the switch back into position
BUS-EN=ON to activate this setting for the next power up(s).
C8000
64ch BNC MADI & AoIP I/O
SW2
BUS-EN
H-CAN
BOOT
ID +16
MASTER
DANTE
1 : 1
This rotary encoder sets the CAN ID of the C8315. The switch positions are
hexadecimal numbers (0x0 to 0xF). The CAN address also defines the
location of the module icon within the GUI overview of rows three to six.
ON
= The output configuration will be taken from the NV (non volatile)
memory after power up.
OFF = will set all bus outputs to Tri-State-Mode (inactive).
Now you may use the frame controller to configure the board.
This configuration will automatically be stored into the NV memory
To enable the configuration for the next power up you must
pull out the module and set BUS-EN=ON again.
C8315
INIT
BDS
POWER:
OK /
FAIL
3/20