Electrical connection

Make sure that the characteristics of the available power supply correspond to those of your dryer,
indicated on its identification plate, and that the cable section and other line accessories can
supply the necessary power.
The machine leaves the factor with the complete electrical installation, and therefore you will
only have to remove the cover on the back of the dryer and connect each of the terminals to the
three phases L1, L2, L3 and neutral N to the terminals of the general switch.
It is COMPULSORY to insert a circuit breaker and differential switch between the wiring and the
mains, and the sensitivity of the differential switch must be 300 mA. Higher sensitivity, for
example 30 mA, common in domestic installations may cause operating anomalies in the
machine.
Connect the three phases, neutral in the general switch and the protection cable to earth on the
electrical components panel according to the following table (section in mm
Correct earthing is essential to guarantee the safety of users and correct
operation.
Voltage and Standard Wiring
Frequency
Cable Section 230 I + T
/Fuse
Cable Section 230 III
+T/Fuse
Cable Section 400 III + N +
T / Fuse
Cable Section 230 I + T/
Fuse
Cable Section 230 III +
/Fuse
Cable Section 400 III + N +
T / Fuse
Voltage and Standard Wiring
Frequency
Cable Section 230 I + T/
Fuse
Cable Section 230 III +
/Fuse
Cable Section 400 III + N +
T / Fuse
Cable Section 230 I + T
/Fuse
Cable Section 230 III +
/Fuse
Cable Section 400 III + N +
T / Fuse
DS/DL-11
STANDARD
230I(CG,CV
)-
400VIII+N+
V
G(CE)
Hz
50 / 60 (3)
Nº x mm2 / A
3 x 35 / 63
Nº x mm2 / A
4 x 10 / 40
Nº x mm2 / A
5 x 4 / 25
Nº x mm2 / A
3 x 1,5 / 20
Nº x mm2 / A
4 x 1,5 / 20
Nº x mm2 / A
5 x 1,5 / 20
STANDARD
230I(CG,CV)-
V
400VIII+N+G(CE)
Hz
50 / 60 (4)
Nº x mm2 / A
-
Nº x mm2 / A
4 x 35 / 100
Nº x mm2 / A
5 x 16 / 63
Nº x mm2 / A
3 x 1,5 / 20
Nº x mm2 / A
4 x 1,5 / 20
Nº x mm2 / A
5 x 1,5 / 20
DS/DL-17
EXCELLEN
CE
STANDARD
230I(CG,CV
230I(CG,CV
)-
)-
400VIII+N+
400VIII+N+
G(CE)
G(CE)
50 / 60 (4)
50 / 60 (3)
3 x 35 / 63
-
4 x 10 / 40
4 x 16 / 63
5 x 4 / 25
5 x 10 / 32
3 x 1,5 / 20
3 x 1,5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20
DS/DL-28D
EXCELLENCE
230I(CG,CV)-
400VIII+N+G(CE)
50 / 60 (4)
-
4 x 50 / 125
5 x 16 / 63
3 x 1,5 / 20
4 x 1,5 / 20
5 x 1,5 / 20
2
).
DS/DL-23
EXCELLEN
CE
STANDARD
230I(CG,CV
230I(CG,CV
)-
)-
400VIII+N+
400VIII+N+
G(CE)
G(CE
50 / 60 (4)
50 / 60 (4)
-
-
4 x 16 / 63
4 x 25 / 80
5 x 10 / 32
5 x 10 / 40
3 x 1,5 / 20
3 x 1.5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20
DS/DL-35D
STANDARD
EXCELLENCE
230I(CG,CV)-
230I(CG,CV)-
400VIII+N+G(CE)
400VIII+N+G(CE)
50 / 60 (4)
50 / 60 (4)
-
4 x 50 / 125
4 x 50 / 125
5 x 16 / 63
5 x 16 / 63
3 x 1,5 / 20
3 x 1,5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20
EXCELLEN
CE
230I(CG,CV
)-
400VIII+N+
G(CE
50 / 60 (4)
-
4 x 25 / 80
5 x 10 / 40
3 x 1.5 / 20
4 x 1,5 / 20
5 x 1,5 / 20
-
81