The message below is displayed when the connected sensor has a Sensor ID that is already configured in the gateway. When this oc-
curs, additional options are provided as shown.
Press the corresponding number to perform the action described.
- Option 1 will reconfigure the sensor with the next Sensor ID available in the system. Do this when adding a sensor to a
network that was already part of a different network, but was not erased from the previous gateway.
- Option 2 will erase all configuration data from the Sensor.
- Option 3 will erase all configuration data from the Sensor and remove it from the gateway.
- Option 4 will update the sensor to match the gateway's communication configuration.
• Note - this option is only available if the configuration data is different between the sensor and gateway.
Note - If a configuration error occurs due to a faulty connection of the USB port/cable such as electrical noise, the system may
display some unknown data but will conclude with a message that the sensor configuration has not been changed. Press the
SPACE BAR to try configuration again, or disconnect and reconnect the USB cable.
After the primary gateway is configured with the desired sensors, it is recommended to capture the configuration data by using
Option L, discussed below, to list the sensors on the screen. Using either the "Print Screen" button or copying/pasting the data
from the screen into a text file can be used.