The Philips EasySense fixture-mount sensor is the ideal solution for
per-fixture control of new light fixtures. It combines occupancy sensing,
daylight harvesting and task tuning in a single, compact package for easy
OEM fixture assembly. EasySense operates with the established Philips
Advance Xitanium SR LED driver standard to make a simple two-wire
connection between sensor and driver, thus eliminating the need for
multiple components and auxiliary devices. The result is a cost-effective and
easy-to-design-in solution ideal for energy-savings and code-compliance
strategies. An intuitive app makes configuration and commissioning during
and after installation fast and easy using Philips field apps.
EasySense with advanced grouping functionaility enables addition of
qualified wireless switches. Up to 40 sensors can be grouped to a switch
using Philips field apps. In addition to easily adding user control to a
space, the grouping feature facilitates auto-off/manual-on and auto-off/
partial-on use cases. Furthermore, advanced grouping allows scene setting
(e.g., presentation mode for a conference room), as well as occupancy
sharing (i.e., fixtures within a group can be programmed to remain at
prescribed light levels so long as occupancy is detected anywhere in
the group).
EasySense for advanced grouping (SNS200) is also DLC qualified and listed
in the QPL for Networked Lighting Controls.
Commercial Product Name
EasySense Fixture-Mount Sensor
Order Code
SNS200
SNS201

Advertisement

loading

Summary of Contents for Philips EasySense

  • Page 1 EasySense with advanced grouping functionaility enables addition of qualified wireless switches. Up to 40 sensors can be grouped to a switch using Philips field apps. In addition to easily adding user control to a space, the grouping feature facilitates auto-off/manual-on and auto-off/ partial-on use cases.
  • Page 2 • Compact size, 2-wire connection • Enables auto-off/manual-on and auto-off/ • Classrooms partial-on application • Operates with Philips Advance Xitanium SR • Storage and break areas LED drivers and qualified wireless switches • Cost-effective solution for energy-savings and code-compliancy strategies •...
  • Page 3 33ft line-of-sight Max Distance Fixture-to-Fixture 40ft line-of-sight No. Switches per Group 5 max Field Configuration via NFC or IR, parameters set via Philips field apps Compatible LED Drivers Driver Model Number Description XI040C110V054VPT1 Xitanium 40W 0.1-1.1A 27-54V 120-277V SR XI075C200V054VPT1 Xitanium 75W 0.1-2.0A 27-54V 120-277V SR...
  • Page 4 EasySense fixture-mount sensor Sensor Dimensions (in./mm) 1.72 [43.8] MAX 1.97 [50.0] MAX Mounting h R0.09 [2.3] Mounting Dimensions (in./mm) 1.72 [43.8] MAX Accessory Mounting Ring Part Number SMR-50 / Set of 50 Mounting in U-shaped slot in sheet metal (max thickness 1 mm), tolerance +0.2mm/-0.0mm •...
  • Page 5: Wiring Diagram

    EasySense fixture-mount sensor Wiring Diagram Connectors EASYSENSE LED+ LED+ LED- XITANIUM SR LED- Use 18AWG solid copper wire, LED DRIVER RSET2 GROUND rated >=600V/90C. LINE SGND Strip wire to 3/8”. NEUTRAL Connectors NFC ANTENNA (non-polarized) EasySense_PLt-16199DS_ES Adv Grouping DS_061818 06/18 page 5 of 12...
  • Page 6: Occupancy Sensing

    Major movement (person moving ≥ 3.0'/s or 0.9m/s). Height Minor Movement Major Movement 8'/2.4m 10'/2.9m 9'/2.7m 15'/4.5m 9'/2.9m 10'/3m 12'/3.6m 11'/3.4m 18'/5.4m 12'/3.6m Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of EasySense. EasySense_PLt-16199DS_ES Adv Grouping DS_061818 06/18 page 6 of 12...
  • Page 7 EasySense fixture-mount sensor Occupancy Sensing (continued) Full-On Sequence (Default) Eco-On Level = Task Level Eco-on level/Task Level (con gurable) Hold time (con gurable) Background level (con gurable) Prolong time (con gurable) Switch-on sequence Switch-o sequence Partial-On Sequence (Configurable) Eco-On Level < Task Level...
  • Page 8 EasySense fixture-mount sensor Daylight Sensor The light sensor measures the total amount of light in a circular field of ≈80% of the PIR detection area. The following aspects should be observed during installation: • Minimum distance from the window ≥ 2.0'/0.6m.
  • Page 9: Default Factory Settings

    EasySense fixture-mount sensor Philips Field Apps: EasySense NFC and EasySense IR EasySense parameters can be configured via Philips field apps. Two versions are available: EasySense NFC – This app allows configuring EasySense parameters only when you can physically access the sensor with a smartphone.
  • Page 10: Ceiling-Mount Option

    Four drivers per sensor maximum. Polarity must be maintained. White Neutral LED+ Black Line Blue LED- Green Ground Orange RSET2 Purple Green SGND Brown Note: Refer to www.philips.com/easysense for quick installation guide. EasySense_PLt-16199DS_ES Adv Grouping DS_061818 06/18 page 10 of 12...
  • Page 11 EasySense fixture-mount sensor Ceiling-Mount Option Sensor Dimensions (in/mm) 1.240 (31.5) REF. 1.811 (46) REF. EasySense_PLt-16199DS_ES Adv Grouping DS_061818 06/18 page 11 of 12...
  • Page 12 (Default 20% "On") Off/Dim down Off/Dim down Philips Lighting North America Corporation © 2018 Philips Lighting Holding B.V. All rights reserved. 10275 W. Higgins Road, Rosemont IL 60018 Philips reserves the right to make changes in specifications Tel: 800-322-2086 Fax: 888-423-1882...