Download Print this page

Altronic CD200D Installation Instructions Manual page 32

Digital ignition system

Advertisement

12.11 2 READ/WRITE REMOTE CONTROL REGISTERS FOR
ENGINE CONTROL SYSTEM TABLE (RAM ONLY) **
ADDRESSES
FUNCTION
40101
Remote Cont Energy 3,2,1,0 RAM
40102
Remote Cont Global Ret Deg RAM
12.12 12 READ/WRITE REMOTE CONTROL REGISTERS FOR
CYLINDER RET. TABLE (RAM ONLY) **
ADDRESSES
FUNCTION
40103
OUTPUT A (01) Indv Ret Deg RAM
40104
OUTPUT B (02) Indv Ret Deg RAM
40105
OUTPUT C (03) Indv Ret Deg RAM
40106
OUTPUT D (04) Indv Ret Deg RAM
40107
OUTPUT E (05) Indv Ret Deg RAM
40108
OUTPUT F (06) Indv Ret Deg RAM
40109
OUTPUT K (07) Indv Ret Deg RAM
40110
OUTPUT L (08) Indv Ret Deg RAM
40111
OUTPUT M (09) Indv Ret Deg RAM
40112
OUTPUT N (10) Indv Ret Deg RAM
40113
OUTPUT P (11) Indv Ret Deg RAM
40114
OUTPUT R (12) Indv Ret Deg RAM
40115
OUTPUT S (13) Indv Ret Deg RAM
40116
OUTPUT T (14) Indv Ret Deg RAM
40117
OUTPUT U (15) Indv Ret Deg RAM
40118
OUTPUT V (16) Indv Ret Deg RAM
12.13 7 READ/WRITE MISC. REGISTERS
ADDRESSES
FUNCTION
40122
Crank Counter
40123
Start Counter
40124
Cycle Counter HIGH
40125
Cycle Counter LOW
REG40005 MSB=BAUD LSB=NODEID fixed
40126
9600n81:node1
40127
Cold Boot (powerup) Count
40128
Warm Boot ( reset ) Count
* Registers reordered
** New registers
*** Registers removed
CD200D II 4-17 Addendum
All rights reserved © ALTRONIC, LLC 2017