Indicates the number of times the microprocessor has restarted without a
complete loss of power.
10.43 Graphic Display:
The CD200D Terminal Software provides a real time graphic display of the
secondary diagnostic numbers, global engine timing (y-axis/10) and engine
speed (y-axis x 10).
11.0 CD200D UNIT LED DIAGNOSTIC BLINK CODES
11.1
CD200D IGNITION BLINK CODES:
Whenever the LED Diags status flag is enabled (blue) by using the CD200D
Terminal Software, the blinking pattern of the LED on the side of the CD200D
case can be used to interpret the general status of the CD200D diagnostics
without the use of the Terminal Software. Within each group of conditions
described below, the possible diagnostic states are listed according to their
number of blinks. The LED is ON for about 2 seconds between each blink
sequence and the blinks occur evenly spaced at a faster rate.
11.2
LED SIGNALS WITH THE ENGINE STOPPED:
ON – Steady
= READY (new power up or last start attempt aborted)
ON – 1 Blink – ON = FIRED LAST TIME ROTATING (stopped due to stall)
ON – 2 Blink – ON = SHUTDOWN (By grounding G-LEAD when running)
ON – 3 Blink – ON = SHUTDOWN (By Remote Serial Request when running)
ON – 4 Blink – ON = SHUTDOWN (By Overspeed when running)
ON – 5 Blink – ON = WRONG DISK PATTERN
ON – 6 Blink – ON = LOW SUPPLY VOLTAGE (Below Threshold when running)
11.3
LED SIGNALS WITH ENGINE CRANKING:
Rotating, and still below running RPM.
ON/OFF/ON/OFF = PURGING (off first input pulse, toggles each revolution of purge)
ON – Steady
= FIRING NORMALLY (RPM below running set point value)
OFF
= WRONG DISC PATTERN DETECTED
11.4
LED SIGNALS WITH ENGINE RUNNING:
When firing, and above run speed.
ON – Steady
= FIRING NORMALLY (No Diagnostics to Report)
ON – 1 Blink – ON = OPEN SECONDARY ALARM
ON – 2 Blink – ON = PRIMARY SHORT ALARM
ON – 3 Blink – ON = PRIMARY OPEN ALARM
ON – 4 Blink – ON = NO CHARGE ALARM
ON – 6 Blink – ON = LOW SUPPLY VOLTAGE