Akytec ITP14 User Manual

Universal process indicator

Advertisement

Quick Links

ITP14
Universal process indicator
User guide
ITP14_2018.03_0272_EN
© All rights reserved
Subject to technical changes and misprints
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 ·
www.akytec.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ITP14 and is the answer not in the manual?

Questions and answers

Summary of Contents for Akytec ITP14

  • Page 1 ITP14 Universal process indicator User guide ITP14_2018.03_0272_EN © All rights reserved Subject to technical changes and misprints akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 2: Table Of Contents

    Maintenance ..............................9 Transportation and storage ......................... 9 Scope of delivery ............................9 Appendix A. Dimensions ............................ 9 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 3: Overview

    Storage temperature IP Code front IP65, rear IP20 Protection class Relative humidity up to 80% (at +35°C, non-condensing) akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 4: Intended Use

    For circuit integrity check use only the measuring device with the output voltage max. 4.5 V to prevent the device damage. Disconnect the sensor in case of higher voltage. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 5: Input

    As a precaution against inadvertent current reversal on output, a parallel diode (U NOTICE ≥ 1.3U, I ≥ 1.3I) is usually included in the output circuit. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 6: Operation

    Alarm within limits − Alarm outside limits The safe output state can be selected in the parameter out.E. Fig. 6.1 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 7: Alarm

    Check the input signal 4-20 mA I > 22 mA the selected signal 0-10 V U > 11 V akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 8: Programming

    SQrt Square root function SQrt ---- 0000 ---.- 000.0 di.P Decimal point ---.- di.P --.-- 00.00 -.--- 0.000 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 9 1. The minus sign is displayed in the most significant digit, together with 1. The display range is -199.9...999.9 if di.P = ---.-, akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 10: Maintenance

    To prevent the device spinning, the borehole in the front panel must correspond to the dimensions in Fig. A.2. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...

This manual is also suitable for:

Itp14-g

Table of Contents