Installing Sesto Senso On Telescope - PrimaLuceLab SESTO SENSO Manual

Table of Contents

Advertisement

P r i m a L u c e L a b i S r l
First, you need to locate the bushing (details 6-7-8-9-10) for use with
the focuser you have, (figure 2) slightly screw the grubscrews (details
11A and 11B) into the bushing and insert the bushing within the SE-
STO SENSO body (detail 1). Check that the crankshaft groove is facing
upwards. The large hole of the bushing should point towards the mo-
tor pin, the bushing should be inserted until it engages with the motor
pin. At this point you can use the small allen screw (detail 5) to screw
the two grubscrews (detail 11A) by passing through the special hole on
the aluminum body of SESTO SENSO.
In order to connect SESTO SENSO to the focuser (figure 3) of your telescope, you
move the manual focus micrometric knob by unscrewing the screw normally present on the knurled knob. After pulling it
out, you also need to disconnect the larger knob on the focuser, always by means of an allen screw on the knob. On some
plastic-covered focusers, you need to remove the plastic to access the disassembly screw.

Installing SESTO SENSO on telescope

figure 3
p a g e ! 3
S E S T O S E N S O u s e r m a n u a l
figure 2
m u s t r e-

Advertisement

Table of Contents
loading

Table of Contents