Amana MBVC Series Installation Instructions Manual
Amana MBVC Series Installation Instructions Manual

Amana MBVC Series Installation Instructions Manual

Blower cabinet
Hide thumbs Also See for MBVC Series:

Advertisement

MBVC
BLOWER CABINET
INSTALLATION INSTRUCTIONS
C
ONTENTS
.............................................................................. 1
E
D
(ESD) P
LECTROSTATIC
ISCHARGE
........................................................... 2
...................................................................... 2
.......................................................................... 2
................................................................... 3
.................................................................................... 3
: .......................................................... 3
......................................................... 3
................................................................................. 3
.............................................................. 3
B
.................................................................... 3
............................................................. 4
............................................................... 4
................................................................ 5
V
................................................................... 5
............................................................... 6
C
B
...................................................................... 6
....................................................................... 10
E
D
LECTROSTATIC
ISCHARGE
...................................................................... 10
............................................................... 10
................................................................................ 10
............................................................... 10
....................................................................... 11
............................................................................. 13
.......................................................... 13
............................................................. 13
....................................................................... 19
NOTICE
I
"E
"
F AN
C
ERROR IS ENCOUNTERED ON STARTUP
DIP
ELECTRIC HEATER
SWITCHES HAVE BEEN SET TO THE APPROPRIATE
. S
7
HEATER SIZE
EE PAGES
AND
DIP
DELIVERY AND
SWITCH SETTINGS
THIS PRODUCT CONTAINS ELECTRONIC COMPONENTS WHICH REQUIRE A DEFINITE
GROUND. PROVISIONS ARE MADE FOR CONNECTION OF THE GROUND. A DEDI-
CATED GROUND FROM THE MAIN POWER SUPPLY OR AN EARTH GROUND MUST
BE PROVIDED.
..................................... 1
RECAUTIONS
....................................................... 2
,
................................. 2
I
.............................. 3
.................................................... 5
...................................................... 5
............................................ 5
................................... 10
..................................... 11
,
VERIFY THAT THE
8
FOR THE HEATER KIT AIRFLOW
.
is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.
© 2013, 2015-2017 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.daikincomfort.com - www.goodmanmfg.com - www.amana-hac.com
P/N: IO-438E
Date: December 2017
I
NTRODUCTION
This booklet contains the installation and operating instructions
for your modular blower cabinet. All warnings and precautions
within this booklet must be observed. Improper installation can
result in problems ranging from noisy operation to property or
equipment damages, dangerous conditions that could result in
injury or personal property damage and that are not covered by
the warranty. Read this booklet and any instructions packaged
with accessories prior to installation. Give this booklet to the user
and explain its provisions. The user should retain this booklet for
future reference.
NOTE: Upon start up in communicating mode the circuit board
may display an "Ec" error. This is an indication that the dip switches
on the control board need to be configured in accordance with
the Electric Heating Airflow Table in this manual. Configuring the
dip switches and resetting power to the unit will clear the error
code.
E
LECTROSTATIC
NOTE: Discharge body's static electricity before touching unit. An
electrostatic discharge can adversely affect electrical components.
Use the following precautions during modular blower installation
and servicing to protect the integrated control module from dam-
age. By putting the modular blower, the control, and the person
at the same electrostatic potential, these steps will help avoid ex-
posing the integrated control module to electrostatic discharge.
This procedure is applicable to both installed and uninstalled (un-
grounded) blowers.
1. Disconnect all power to the blower. Do not touch the
integrated control module or any wire connected to the
control prior to discharging your body's electrostatic charge
........... 14
to ground.
2. Firmly touch a clean, unpainted, metal surface of the
modular blower near the control. Any tools held in a
person's hand during grounding will be discharged.
3. Service integrated control module or connecting wiring
following the discharge process in step 2. Use caution not
to recharge your body with static electricity; (i.e., do not
move or shuffle your feet, do not touch ungrounded
objects, etc.). If you come in contact with an ungrounded
object, repeat step 2 before touching control or wires.
4. Discharge your body to ground before removing a new
control from its container. Follow steps 1 through 3 if
installing the control on a blower. Return any old or new
controls to their containers before touching any
ungrounded object.
D
(ESD) P
ISCHARGE
RECAUTIONS

Advertisement

Table of Contents

Troubleshooting

loading

Summary of Contents for Amana MBVC Series

  • Page 1: Table Of Contents

    MBVC © 2013, 2015-2017 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 BLOWER CABINET www.daikincomfort.com - www.goodmanmfg.com - www.amana-hac.com INSTALLATION INSTRUCTIONS P/N: IO-438E Date: December 2017 NTRODUCTION ONTENTS ................1 NTRODUCTION This booklet contains the installation and operating instructions (ESD) P ........
  • Page 2: Checking Product Received

    HECKING RODUCT ECEIVED Upon receiving the unit, inspect it for damage from shipment. Claims for damage, either shipping or concealed, should be filed immediately with the shipping company. Check the unit model number, specifications, electrical characteristics and accessories to determine if they are correct. In the event an incorrect unit is shipped, it must be returned to the supplier and must NOT be installed.
  • Page 3: Features

    ENERAL NFORMATION The MBVC Blower Cabinets are used in combination with a cased evaporator coil. This combination of blower and coil functions as the indoor part of a split air-conditioning system, and may be matched with a remote condensing or heat pump unit. The blower cabinet can also function as an electric furnace when used with an electric heater.
  • Page 4: Counterflow Installation

    OUNTERFLOW NSTALLATION For counterflow installations, the evaporator coil cabinet must sit on top of the blower cabinet (Figure 3). NOTE: All panels should be in place when installing the unit. NOTE: Supply ductwork for counterflow applications, must be Class I. However, if combustible ductwork is used, sheet metal protection is required.
  • Page 5: Electrical Connections

    LECTRICAL ONNECTIONS WARNING Consult the local power company and local codes before install- LL WIRING MUST COMPLY WITH APPLICABLE LOCAL AND NATIONAL ing this unit. All wiring must be in accordance with the National CODES YPE AND LOCATION OF FUSED DISCONNECT SWITCH MUST Electrical Code as well as all local codes.
  • Page 6: Auxiliary Alarm Switch

    Typical Single-Stage Cool, UXILIARY LARM WITCH R C G Single-Stage Heat The control is equipped with two Auxiliary Alarm terminals labeled Heat Pump Thermostat CAS which can be utilized with communicating mode setups (typi- Air Handler 2 R C W1 W2 Y1 Integrated Control Module DEHUM cally used for condensate switch wiring but could be used with...
  • Page 7 The ramping profiles are selected using DIP switches 5 and Tap A Tap B Tap C Tap D* 6. Refer to Figure 14 for switch positions and their corresponding taps. Refer to the bullet points below for a description of each ramping profile. Verify profile selection by counting the green CFM LED blinks and timing each step of the ramping profile.
  • Page 8 • Profile C ramps up to 82% of the full cooling demand airflow and operates there for approximately 7 1/2 minutes. The motor then steps up to the full demand airflow. Profile C also has a one (1) minute 100% OFF delay. 100% CFM Figure 17 - Profile C •...
  • Page 9 Speed Selection Dip Switches Figure 18 - Profile D Cool Adjust Profile Continuous Selection Selection Selection Switches Switches Switches Speed Profiles Pre-Run Short-Run OFF Delay Low Stage High Stage Model Cool Cool ------- -------- 60 sec/100% ------- 30 sec/50% 60 sec/100% ------- 7.5 min/82% 60 sec/100%...
  • Page 10: Troubleshooting

    ROUBLESHOOTING AULT ECALL The integrated control module is equipped with a momentary push- (ESD) P LECTROSTATIC ISCHARGE RECAUTIONS button switch that can be used to display the last six faults on the 7 segment LED display. The control must be in Standby Mode (no NOTE: Discharge body’s static electricity before touching unit.
  • Page 11: Control Wiring

    ONTROL IRING NOTE: Refer to section Electrical Connections for 208/230 volt System Operating System Airflow Demand Source line connections to the modular blower. Mode Cooling Air Conditioner NOTE: A removable plug connector is provided with the control to make thermostat wire connections. This plug may be removed, Air Conditioner + Heating Air Handler...
  • Page 12 ODULAR LOWER DVANCED EATURES DIAGNOSTICS Submenu Item Indication/User Modifiable Options Comments Fault 1 (FAULT #1) Most recent fault For display only Fault 2 (FAULT #2) Next most recent fault For display only Fault 3 (FAULT #3) Next most recent fault For display only Fault 4 (FAULT #4) Next most recent fault...
  • Page 13: Diagnostics

    These tools are: red communications LED, green receive (Rx) LED, IAGNOSTICS and LEARN button. Accessing the modular blower’s diagnostics menu provides ready • Red communications LED – Indicates the status of the access to the last six faults detected by the modular blower. Faults network.
  • Page 14: Andler Diagnostic Codes

    ROUBLESHOOTING NFORMATION ANDLER IAGNOSTIC ODES...
  • Page 15 ROUBLESHOOTING NFORMATION ANDLER IAGNOSTIC ODES...
  • Page 16 ROUBLESHOOTING NFORMATION ANDLER IAGNOSTIC ODES...
  • Page 17 ROUBLESHOOTING NFORMATION ANDLER IAGNOSTIC ODES...
  • Page 18 ROUBLESHOOTING NFORMATION ANDLER IAGNOSTIC ODES 7 SEGMENT LED DES CRIPTION OF CONDITION (characters will alternate) (no display) INTERNAL CONTROL FAULT / NO POWER STANDBY, WAITING FOR INPUTS HEATER KIT TOO LARGE, TOO SMALL, OR NO MATCH FUSE OPEN AUXILIARY SWITCH OPEN DATA NOT ON NETWORK INVALID DATA ON NETWORK INVALID MEMORY CARD DATA...
  • Page 19: Troubleshooting Information : Air H Wiring Diagram

    IRING IAGRAM HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 40 VA TRANS FORMER, SEE N OTE 1 230 VAC GRND GRND 208 VAC 24 VAC DISCONNECT...
  • Page 20 AIR HANDLER AIR HANDLER HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDATIONS We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a qualified servicer. REPLACE OR CLEAN FILTER An alternate cleaning method is to use one of the products listed in TP-109* to clean the coils.
  • Page 21 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 22 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 23 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 24 You can also scan the QR code on the right to be directed to the Product Registration Page. DAIKIN NOTE: SPECIFICATIONS AND PERFORMANCE DATE LISTED HERIN ARE SUBJECT TO CHANGE WITHOUT NOTICE. Visit our website at www.daikincomfort.com, www.goodmanmfg.com or www.amana-hac.com for information on: • Products •...

This manual is also suitable for:

Mbvc 2000Mbvc1200Mbvc 1600

Table of Contents