  • Page 1 78-5295-250 3/18 3 2 1 DZ-2500 Switch Block CSM2 6-85295 LCS PDI CABLES PROGRAM AC Power use either connector Lionel Custom Switch Machine Controller (CSM2) Owner's Manual...
  • Page 2: Table Of Contents

    Finding the correct ID for each of the CSM2’s Blocks Appendix Operation of LEDs Specifications of the LCS CSM2 Lionel Limited Warranty Policy & Service The following Lionel marks are used throughout this Owner’s Manual and are protected under law. All rights reserved. ® ® Lionel ®...
  • Page 3: What Is Lionel's Layout Control System

    What is Lionel’s Layout Control System? LCS doesn’t replace your existing Lionel Legacy Control system. It adds to it! You can control your layout from Lionel Cab Remote controllers or from smart devices like an Apple iPad and run locomotives, operate track switches, accessories and lighting. Create automatic events to control passing locomotives and other layout accessories or switches.
  • Page 4: Lcs Csm2 Module

    TMCC communication which allows the user to control the switch machine from a Cab-1, Cab-1L, or Cab2 remote. The CSM2 also allows for control of the switch machine through the LCS APP and provides the throw position for up to 7 machines! •...
  • Page 5: Installing Your First Lcs Device

    LCS component, please skip ahead to the next section titled “Installing additional LCS devices.” When installing a new LCS system, the process you will follow depends on which (if any) Lionel Command Base is to be connected to your LCS system. Following sections describe starting a new LCS installation with a Legacy Base, a Base-1L or without any command base.
  • Page 6: Installing A New Lcs System With A Legacy Base

    Figure 4. Installing a new LCS system with a LEGACY Base Once connected and powered-up, the yellow LED on the Legacy Base will blink once every second. With this setup, you can control Lionel locomotives and Layout Control System products using a Legacy Remote(s) and optionally CAB-1L remote(s).
  • Page 7: Installing A New Lcs System With A Base-1L

    Figure 5. Installing a new LCS system with a Base-1L Once connected and powered-up, the red LED on the Base-1L will blink once every second. With this setup, you can control Lionel locomotives and Layout Control System products using a CAB-1L remote(s).
  • Page 8: Installing Lcs With Legacy And Trainmaster Command Bases

    Installing Your First LCS Device Installing LCS with Legacy AND TrainMaster Command Bases he following instructions apply ONLY if you are using one or more original CAB-1 remotes with a Legacy command base. It is not necessary to follow these instructions to use the CAB-1L remote with a Legacy command base.
  • Page 9 Once connected and powered-up, the yellow LED on the Legacy Base will blink once every second. With this setup, you can control Lionel locomotives and Layout Control System products using any combination of LEGACY Remotes, CAB-1L remotes and original CAB-1 remotes.
  • Page 10: Installing A New Lcs System With No Command Base

    DCC. An LCS WiFi is required, as are one other LCS module (such as ASC2 or BPC2). To install a new LCS system on a layout that does NOT include Lionel Command Base: 1. Connect the DC wall-pack to the female cable-mount connector of the LCS DB-9 Cable.
  • Page 11: Installing Additional Lcs Devices

    The order of devices in the “chain” is up to you. The only exception is that an LCS WiFi must be the first device in the chain if no Lionel Command Base is present. To connect each additional LCS device: 1.
  • Page 12: Configuring Your Csm2

    Configuring Your CSM2 he illustration below shows the names and locations of each switch, connector, and indicator light on you LCS CSM2 module. The function of each is described on following pages. A – Screw terminal for serial data output and 7 switch-sense screw terminals for DZ-2500 switch machines.
  • Page 13: Wiring Accessory Transformer To Relay Power Terminals

    “A” and “U” as shown in Figure 9 below. If your installation includes more than one CSM2, they can share the same accessory transformer as long as the combined current draw of the relays does not exceed the capacity of the accessory transformer (see specifications, electrical at the end of this document).
  • Page 14: Wiring The Dz-2500 Switch Machine To The Csm2

    CSM2 provides the TMCC serial data to the DZ-2500 switch machine so that the machine can be controlled from a Lionel CAB remote or the LCS App. Note that the CSM2 does not provide power to the switch machines, it simply throws them. The CSM2 can also monitor the throw position of up to 7 DZ-2500s.
  • Page 15 Configuring Your CSM2 Wiring the DZ-2500 Switch Machine to the CSM2 continued Figure 11. Wiring a single DZ-2500 Switch Machine to the CSM2...
  • Page 16 If you want the “straight” direction to physically be the straight portion of track in the switch, then you would connect the DZ-2500’s yellow wire to the CSM2. If you want the curved or turnout portion of the track to be the “straight” direction, then you would connect the DZ-2500’s green wire to the CSM2.
  • Page 17: Wiring The Dz-2500 Switch Machine To The Csm2 Using The Break-Out Board

    Service (Part number 1908010). The Breakout Board offers many advantages over installing the DZ-2500 switch machines directly to the CSM2. See figure 13 on page 18. • Ease of wiring – The DZ-2500 hooks right into the Breakout Board using a simple push button connector, so adding or removing only takes seconds.
  • Page 18 Configuring Your CSM2 Wiring the DZ-2500 Switch Machine to the CSM2 using the Break-out Board continued BLACK GREEN YELLOW WHITE BLUE Figure 13. Wiring DZ-2500 to CSM2 using Lionel Breakout Board...
  • Page 19 Carefully read the labels on the Breakout Board. 2. Connect the serial line from the CSM2 to the Breakout Board. This line can also be daisy-chained to the next Breakout Board if more than one DZ-2500 is being used.
  • Page 20: Programming The Dz-2500 Switch Machine

    The LEDs will now flash rapidly waiting for an address. 3. Using a Lionel CAB remote, press SW for switch, enter the desired switch number (for example, 15), then press SET. The green LED should then be lit indicating that the TMCC ID has been set.
  • Page 21: Configuring The Dz-2500 Switch-Sense Connections

    2. Press and hold the CSM2 PGM button for 1 second. The red LED will begin blinking slowly. 3. On your Lionel CAB remote, press SW (Switch addressing). 4. Enter the desired 1 or 2 digit base address for your CSM2. This should match the TMCC ID of the DZ-2500 connected to switch-sense screw terminal #1.
  • Page 22 Configuring Your CSM2 Configuring the DZ-2500 Switch-Sense Connections continued 3 2 1 DZ-2500 Switch Block CSM2 6-85295 LCS PDI CABLES PROGRAM AC Power use either connector Figure 14. Each switch-sense screw terminal must connect to a DZ-2500 with a corresponding...
  • Page 23: Wiring The Csm2 For Block Power Control

    Configuring Your CSM2 Wiring the CSM2 for Block Power Control hen connected to track power blocks, the CSM2 will be able to switch on and off the power. However, the power to these blocks will simply be passing through the CSM2 relays.
  • Page 24: Csm2 Block Power Control Software Configuration

    4. Sub-mode setting. The 4 TMCC ID choice is recommended. The 1 TMCC ID sub-mode is reserved for future use and won’t work with a Cab remote. See figure 15 on page 24 for the CSM2 configuration flow chart for block power control.
  • Page 25 Maximum = 95) (Optional R coupler key sets “restore last relay settings on power-up”) (select sub-mode) Result Track Track Accessory Accessory TMCC ID 1 TMCC ID TMCC ID 1 TMCC ID Figure 15. CSM2 configuration flow chart for block power control...
  • Page 26: Configuring Your Csm2 For Track Addresses

    1. Turn power to your command base and LCS system ON. 2. Press and hold the CSM2 PGM button for 1 second. The red LED will begin blinking slowly. 3. On your Lionel cab remote, press TR to choose TRACK-address operation.
  • Page 27: Configuring Your Csm2 For Accessory Addresses

    1. Turn power to your command base and LCS system ON. 2. Press and hold the CSM2 PGM button for 1 second. The red LED will begin blinking slowly. 3. On your Lionel cab remote, press ACC to choose ACCESSORY-address operation.
  • Page 28: Track Power Wiring Examples

    Track power should be connected to the terminals on the CSM2. Refer to Figure 8 on page 12, letter B. The label “Block” shows which terminals correspond to power blocks 1 through 4. These blocks share a common connection.
  • Page 29: Wiring For All 4 Power Blocks To A Single Transformer

    CSM2, refer to the wiring diagram below. The Power “A” terminal from the track power transformer must be connected to the COMM terminal on the CSM2. Your track power transformer must have sufficient capacity to operate the combined current draw of all operating locomotives on all active track power blocks.
  • Page 30: Controlling Tracks Wired To The Csm2

    For example, assume your CSM2 has a TMCC base address of “1”. If you would like to operate the block wired to the third terminal of the CSM2, you need to press TR (or ACC), 3 on your CAB remote controller. Then operate that block using Aux1 or Aux2.
  • Page 31: Appendix

    Appendix Operation of LEDs n power up, the Red LED on your CSM2 will turn on for 1 second. If it remains on continuously, this indicates a problem with the LCS PDI cabling or your command base. During operation, the Red LED flickers when commands are passing through the LCS PDI bus.
  • Page 32: Lionel Limited Warranty Policy & Service

    Lionel LLC or any Lionel Authorized Service Station MUST be accompanied by the original receipt for purchase (or copy) from an Authorized Lionel Retailer*, will at the discretion of Lionel LLC, be repaired or replaced, without charge for parts or labor. In the event the defective product cannot be repaired, and a suitable replacement is not available, Lionel will offer to replace the product with a comparable model (determined by Lionel LLC), if available.