_1
/
(100 _ Ta)
8,07
PA
{Exciter Heads 481 2 and 4813)
22\1
PSL
1
J
PA
-
(100 - Ta) 6,67
-
(Exciter Heads 4811 and 4814)
20
PSL
where
P
A
= ambient airdensity
PSL
=
air density at sea level
2. Dynamic rated force is reduced jf the mains voltage is -5% to -15% of nominal.
3. At frequencies above 150 Hz the dynamic rated force is reduced by 2,5% if half of
the available static force is used and is reduced by 10% if the full static force is
used. At frequencies below 150 Hz the dynamic rated force is reduced by 15% if
half of the available static force is used and is reduced by 30% if the full static force
is used
.
4. The system V exciters will normally be opera t ed by Power Amplifier Type 2707
rated at 220 VA. To attain higher performance characteristics the exciter may be in ­
termittently driven by Power Amplifier Type 2708, rated 1200 VA. This permits a
higher dynamic range to be achieved with, for example, random signals. However,
the maximum RMS ratings (e.g. current) must not be exceeded. The 480
1
and
2708 are fully compatible with respect to supply and interlock connections.
9.5.
EXTE
RNAl
DIM EN
SIONS
The externai dimensions of the 4801 T and 4801
S
are given in Figs.9.1 and
9.
2
respec
­
tively.