Chapter 8 Specifications for the ICA Range
Table 8.1 ICA1H (0.1 to 10.1 V)
Electrical and Environmental
Parameter
Supply voltage Range
Operating Current
Operating Temperature Range
Storage Temperature Range
Reverse polarity Protection
Note 1: Not including excitation current.
e.g. when connected to a 350 ohm load cell, excitation current = 5/350 = 14 mA
Total current = 22mA
Measurement
Parameter
Bridge Excitation
Bridge Impedance
Bridge Sensitivity
Output load
Bandwidth
'Zero' adjustment
'Span' adjustment
Linearity
Temperature stability
'Zero' Temperature Stability
'Span' Temperature Stability
FR=Full Range (10 V)
Note 1: Set by calibration resistor
Note: The voltage between either of the power supply connections and the load cell shield should not exceed 50 V.
Any leakage will be greater than 10 M ohms.
Figure 8.1 ICA1H Pad and Potentiometer Positions
21
Mantracourt Electronics Limited – ICA User Manual
Minimum
Typical
13
24
-
8
-40
-
-40
-
-30
-
Minimum
Typical
4.90
5
350
1000
0.5
2.5
5000
-
DC
-
-
±2
-
±8
-
0.02
-
0.0004
-
0.002
Maximum
Units
28
volts
-
85
85
-
volts
Maximum
Units
5.10
volts
5000
ohms
>50
mV/V
-
ohms
1000
-
%FR
-
%FR
-
%FR
0.0015
±%FR/°C
0.0051
±%FR/°C
Notes
mA
Note 1
°C
°C
Notes
Note 1
Hz
At 2.5 mV/V
At 2.5 mV/V