Offset Resistor (R1) vs Load Cell Impedance

The following table gives the value of R1 for various load cell impedances and ±2% FS and 4% FS trim:
Load Cell Impedance
350 Ohms
700 Ohms
1000 Ohms
5000 Ohms
Mantracourt Electronics Limited – ICA User Manual
±2% FS
±4% FS
30k
n/a
100k
27k
180k
60k
1M
430k