  • Page 1 Optical Remote Unit ION™-M7P/17P & Subassemblies (M-cabinet) Manual MF0145A7A...
  • Page 2 All information contained in this manual has been revised thoroughly. Yet CommScope Solutions accepts no liability for any omissions or faults. CommScope Solutions reserves the right to change all hardware and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies.
  • Page 3: Table Of Contents

    HEALTH AND SAFETY WARNINGS 1.3. ABOUT COMMSCOPE SOLUTIONS 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 2. INTRODUCTION 2.1. PURPOSE 2.2. THE ION-M7P/17P (INTELLIGENT OPTICAL NETWORK; MMR) 3. FUNCTIONAL DESCRIPTION 3.1. COMPONENTS OF THE ION-M7P/17P REMOTE UNIT 3.1.1. Fan-Protection Kit 3.1.2. Accessories 4. COMMISSIONING 4.1.
  • Page 4 Manual for ION™-M7P/17P (M-cab) & Subassemblies 5.3. ALARM STATUS 5.4. STATUS LED ALARMS 5.5. EXTERNAL ALARM INPUTS AND OUTPUTS 5.6. TROUBLESHOOTING 6. MAINTENANCE 6.1. GENERAL 6.2. REPLACING THE FAN UNIT 6.3. CLEANING THE HEAT SINK 7. APPENDIX 7.1. ILLUSTRATIONS 7.2. SPECIFICATIONS 7.2.1.
  • Page 5 4-3 Pole mounting (metric dimensions) ............21 figure 4-4 Mounting procedure for fan protection, (metric dimensions)..... 22 figure 4-5 Connector flange of ION-M7P/17P ............24 figure 4-6 Grounding bolt with loosened hex nut ............25 figure 4-7 Grounding bolt, schematic view..............25 figure 4-8 AC mains plug ..................
  • Page 6 Manual for ION™-M7P/17P (M-cab) & Subassemblies For your notes: Page 6 MF0145A7A_uc_FCC_modif.doc...
  • Page 7: General

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System Automatic Level Control BITE Built-In Test Equipment Base Transceiver Station "Conformité Européenne" ("European Conformity") Compact Disk Channel Power Detection Downlink...
  • Page 8: Health And Safety Warnings

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2.
  • Page 9 Manual for ION™-M7P/17P (M-cab) & Subassemblies 12. Before opening the unit, disconnect mains. 13. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures. 14. This unit complies with European standard EN60950. 15.
  • Page 10: About Commscope Solutions

    For technical assistance and support, please also contact the local office or CommScope Solutions directly at one of the addresses listed in the following chapter. Page 10 MF0145A7A_uc_FCC_modif.doc...
  • Page 11: International Contact Addresses For Customer Support

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT Americas: Canada United States CommScope Solutions Canada Andrew LLC, A CommScope Company 505 Consumers Road, Suite 803 620 North Greenfield Parkway Mail Toronto M2J 4V8 Mail Garner, NC 27529 Canada U.S.A.
  • Page 12 E-mail wisupport.austria@commScope.com E-mail wisupport.ch@commScope.com Italy Iberia Region - Spain & Portugal Andrew España S.A. CommScope Italy S.r.l., Faenza, Italy A CommScope Company Avda. de Europa, 4 - 2ª pta. Via Mengolina, 20 Parque Empresarial de la Moraleja Mail Mail 48018 Faenza (RA)
  • Page 13 Manual for ION™-M7P/17P (M-cab) & Subassemblies Czech Republic CommScope Solutions Czech Republic C-Com, spol. s r.o U Moruší 888 Mail 53006 Pardubice Czech Republic +49 871 9659171 (Office) Phone +49 171 4001166 (Mobile) +49 871 9659172 E-mail wisupport@commScope.com Africa & Middle East: Middle East &...
  • Page 14: Introduction

    2.2. THE ION-M7P/17P (INTELLIGENT OPTICAL NETWORK; MMR) The ION-M7P/17P is a multi-band, multi-operator remote unit configuration used in conjunction with a master unit in the ION optical distribution system. This system transports up to two frequency bands simultaneously (700 MHz and 1700/2100 MHz), providing a cost-effective solution for distributing capacity from one or more base stations.
  • Page 15 Manual for ION™-M7P/17P (M-cab) & Subassemblies The ION can be easily set-up and supervised from a graphical user interface (GUI). Remote units are commissioned through the use of built-in test equipment. An auto levelling function compensates for the optical link loss making installation easy and quick.
  • Page 16: Functional Description

    & Subassemblies 3. FUNCTIONAL DESCRIPTION 3.1. COMPONENTS OF THE ION-M7P/17P REMOTE UNIT 3.1.1. Fan-Protection Kit In order to protect the fan unit (e.g. against rain), a protective cover to be mounted over the air inlet is delivered with the unit. For more details see section 4.1.4 Mounting of Fan Protection.
  • Page 17: Commissioning

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 4. COMMISSIONING 4.1. MECHANICAL INSTALLATION 4.1.1. General Read the health and safety warnings in section 1.2 Health and Safety Warnings. 1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met.
  • Page 18 Manual for ION™-M7P/17P (M-cab) & Subassemblies 7. A spacing of 40 mm (1.58 inch) around the unit is required. 8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided.
  • Page 19: Wall-Mounting Procedure

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 4.1.2. Wall-Mounting Procedure  Check the suitability of the wall-mounting kit and the wall.  Mark the position of the drilling Wall mounting with active cooling kit holes (for measurements refer to 0.50 122 ± 0.50 figure 4-1 Wall mounting).
  • Page 20: Pole-Mounting Procedure

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 4.1.3. Pole-Mounting Procedure Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a column or other similar structures. Additional hardware must be used for this type of installation. Such a pole-mounting kit could include two threaded rods M8, two U-beams and mounting material like bolts and nuts.
  • Page 21: Figure 4-3 Pole Mounting (Metric Dimensions)

    Manual for ION™-M7P/17P (M-cab) & Subassemblies Lock washer for M8.0 DIN 127 Washer DIN 125 Lock for folding A2 Form B Optical TESPA screw band, Form B Ø 8.0 screw band ES 119 Remote Unit stainless, 11 mm Hexagon nut M8 DIN 934 Pole Pole...
  • Page 22: Mounting Of Fan Protection

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 4.1.4. Mounting of Fan Protection Since the fan protection is required for the outdoor usage of a stand-alone Remote Unit, the mounting of this optional equipment is also described in this manual.  To install the protective cover of the fan protection kit, first unscrew the four screws with the respective lock washers from the cover of the air inlet of the Remote Unit, and instead, screw in the four spacing bolts M4.0x30 with the four lock washers M4.0 DIN125 that are part of the fan protection kit.
  • Page 23: Electrical Installation

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 4.2. ELECTRICAL INSTALLATION 4.2.1. General Read the health and safety warnings in section 1.2 Health and Safety Warnings. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be the result if the instructions contained in this manual are not followed.
  • Page 24: Connections

    13. Observe the labels on the front panels before connecting or disconnecting any cables. 4.2.2. Connections Alarm N-antenna External RS485 Status output connector alarm input connector Mobile AWS Optical-fibre Mains connector connector Grounding bolt N-antenna connector Mobile LTE700 figure 4-5 Connector flange of ION-M7P/17P Page 24 MF0145A7A_uc_FCC_modif.doc...
  • Page 25: Grounding

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 4.2.3. Grounding Grounding must be carried out. Connect an earth-bonding cable to the grounding connection provided at the outside of the Remote Unit (see section 4.2.2 Connections). Do not use the grounding connection to connect external devices. figure 4-6 Grounding bolt with figure 4-7 Grounding bolt, schematic view loosened hex nut...
  • Page 26: Connection Of The Antenna Cables

    Manual for ION™-M7P/17P (M-cab) & Subassemblies figure 4-8 AC mains plug For the AC power supply connection, a minimum cross section of 1.5 is required. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation.
  • Page 27: Optical Fiber Cable Connection Rules

    Manual for ION™-M7P/17P (M-cab) & Subassemblies Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the Andrew e-catalog.
  • Page 28: Protective Plug

    Manual for ION™-M7P/17P (M-cab) & Subassemblies  The pigtails for the connection between Master and Remote Unit must have a sufficient length. A protection for the feeding into units must be given.  System attenuation and attenuation of optical components must be determined. ...
  • Page 29 Manual for ION™-M7P/17P (M-cab) & Subassemblies For plug assembly, observe the following instruction: 1. Pass one or two contacts through the backshell and the clamp ring. 2. Place the contact(s) on the lower insulation body by pushing the groove of the contact into the cavity.
  • Page 30: Protective-Tube Kit

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 7. Bring the plastic ring over the cable(s), push it into the backshell and compress the seals and plastic ring by screwing the clamp ring tight (no gap) using a spanner with opening 20. *** Screw tight until gap is closed 8.
  • Page 31: Figure 4-10 Tube-Kit Installation

    Manual for ION™-M7P/17P (M-cab) & Subassemblies Protective plug Fiber cable Ring 3/4 Screw the reducer to the protective plug Reducer backshell without any gap! Coupling Place the appropriate seal parts (with) one groove for one contact or two grooves for two contacts) over the cable(s) and push them into Protective tube the backshell!
  • Page 32: Commissioning

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 4.5. COMMISSIONING Read the health and safety warnings in section 1.2 Health and Safety Warnings. Keep these guidelines in mind before continuing to the instructions for commissioning:  Do not operate the Remote Unit without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load.
  • Page 33 Manual for ION™-M7P/17P (M-cab) & Subassemblies Commissioning an ION-M Remote Unit Manual for Remote Start Unit Philips Preperation screwdriver Unpack RU, RU accessories and mounting kit. Mounting kit Spanner, size 13 mm Drilling Mechanical installation machine Fasten wall or pole mounting kit to wall or Dowels pole.
  • Page 34 Manual for ION™-M7P/17P (M-cab) & Subassemblies LED on? Check power switch inside RU (RUs with door). Check mains cabling. Check mains power. LED status Internal Error Change power supply (RUs with a door) Reduce environmental temperature. Eliminate thermal short circuit. Disconnect and connect mains.
  • Page 35: Alarms

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 5. ALARMS 5.1. BITe AND ALARMS The Built-In Test (BITe) concept comprises the monitoring of the power supplies, the power amplifiers and the optical interface. All alarms occurring can be checked via software at the Master Unit. 5.2.
  • Page 36: External Alarm Inputs And Outputs

    Manual for ION™-M7P/17P (M-cab) & Subassemblies Alarms directly related to RU: Change power supply (RUs with door). Power 28 V Replace the affected Remote Unit. Reduce environmental temperature. Temperature Eliminate thermal short circuit. Disconnect and connect mains. Fans should run. If not, replace the fans at I²C Disconnect and connect mains.
  • Page 37: Figure 5-3 Alarm Inputs And Outputs, Standard

    Manual for ION™-M7P/17P (M-cab) & Subassemblies The alarm outputs (open collector output 5 V / 1 mA) are normally low. In case of an alarm they are high active (5 V). They can be used to monitor alarms with an external alarm indicator.
  • Page 38: Troubleshooting

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 5.6. TROUBLESHOOTING The status of the Remote Unit can be checked via the Master Unit (for details please refer to the software manual of the Master Controller). Locally, the status can be checked at the LED, see section 5.4 Status LED Alarms. Page 38 MF0145A7A_uc_FCC_modif.doc...
  • Page 39: Maintenance

    These cleaning intervals depend mainly on the location of the Remote Unit and the corresponding degree of pollution. Maintenance of the ION-M7P/17P should be performed by replacing only components that are contained in this section. Take care not to unintentionally damage the seals on the modules to maintain warranty.
  • Page 40: Replacing The Fan Unit

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 6.2. REPLACING THE FAN UNIT Replacement of the fan unit is not required as a preventative measure. Only if an alarm indicates a malfunctioning of a fan must the unit be exchanged.  Note: Please observe that the fan unit can only be replaced as a whole.
  • Page 41 Manual for ION™-M7P/17P (M-cab) & Subassemblies 5. To mount the new fan unit, re-connect the earth-bonding cable and the fan connector (see step 4). Then, place the fan unit back into its original position and fasten it tight as shown below: 6.
  • Page 42: Cleaning The Heat Sink

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 6.3. CLEANING THE HEAT SINK  Note: Read the health and safety warnings in section 1.2 Health and Safety Warnings as well as the instructions in section 6.1 General before starting with the replacement procedure. Then, proceed as follows: 1.
  • Page 43: Appendix

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 7. APPENDIX 7.1. ILLUSTRATIONS figure 7-1 Installation drawing Page 43 MF0145A7A_uc_FCC_modif.doc...
  • Page 44: Specifications

    Manual for ION™-M7P/17P (M-cab) & Subassemblies 7.2. SPECIFICATIONS 7.2.1. Electrical Specifications Electrical 85 Vac to 264 Vac Mains power 115 Vac or 230 Vac Power supply max. temp., fully 550 watts Power consumption loaded room temp., idle 300 watts Optical Link Optical link connectors E2000/APC 8°...
  • Page 45: Spare Parts

    To replace an FRU, use the appropriate tools. Replacement tools may be ordered from the supplier. If any FRU not contained in the following list needs to be replaced, please contact customer service for additional instructions. Spare Parts List of the Remote Unit ION-M7P/17P Designation: ID No:...
  • Page 46: Index

    Mounting Cleaning the Heat Sink ......... 42 Fan Protection ..........22 Commissioning Pole (Outside)..........20 General ............32 Wall..............19 CommScope Solutions ......... 10 Components Accessories ............. 16 Fan-Protection Kit ..........16 Optical-Fiber Connection Connection Rules Protective-Tube Kit .......... 30 Optical Fibers...........