Battery Charger (Leon-G200 Only) - u-blox LEON-G100 System Integration Manual

Table of Contents

Advertisement

Current [mA]
~150 mA
150
100
50
20-22 mA
0
0.47-2.12 s
Paging period
Current [mA]
150
100
50
20-22 mA
0
Figure 13: Description of the VCC current consumption profile versus time when power saving is disabled: active-mode is
always held, and the receiver and the DSP are periodically activated to monitor the paging channel for paging block reception

1.5.4 Battery charger (LEON-G200 only)

For battery charging functionalities the module is provided with integrated circuitry and software. Two pins are
available to connect the positive pole of the external DC supply used as charger.
Name
Description
V_CHARGE
Charger Voltage Supply Input
CHARGE_SENSE
Charger Voltage Measurement Input
Table 8: Battery charger pins
V_CHARGE and CHARGE_SENSE pins ESD sensitivity rating is 1 kV (HBM JESD22-A114F). A higher
protection level could be required if the lines are externally accessible on the application board. A higher
protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor
array) on the lines connected to these pins if they are externally accessible on the application board.
GSM.G1-HW-09002-G3
LEON-G100 / LEON-G200 - System Integration Manual
~150 mA
38-40 mA
RX
DSP
Enabled
Enabled
ACTIVE MODE
Remarks
V_CHARGE and CHARGE_SENSE pins must be externally
connected together.
V_CHARGE and CHARGE_SENSE pins must be externally
connected together.
Preliminary