Logic Controller; Special Functions; Drive Information - GE Consumer & Industrial AF-60 LP Operating Instructions Manual

Micro drive
Table of Contents

Advertisement

6.2.14 13-** Logic Controller

Parameter
Parameter Description
Number
13 - 00
Logic Controller Mode
13 - 01
Start Event
13 - 02
Stop Event
13 - 03
Reset Logic Controller
13 - 10
Comparator Operand
13 - 11
Comparator Operator
13 - 12
Comparator Value
13 - 20
Logic Controller Controller Timer
13 - 40
Logic Rule Boolean 1
13 - 41
Logic Rule Operator 1
13 - 42
Logic Rule Boolean 2
13 - 43
Logic Rule Operator 2
13 - 44
Logic Rule Boolean 3
13 - 51
Logic Controller Event
13 - 52
Logic Controller Action
6

6.2.15 14-** Special Functions

Parameter
Parameter Description
Number
14 - 01
Motor Noise (Carrier Freq.)
14 - 03
Overmodulation
14 - 12
Function at Mains Imbalance
14 - 20
Reset Mode
14 - 21
Automatic Restart Time
14 - 22
Restore Factory Settings
14 - 26
Action At Inverter Fault
Energy Savings Minimum Magneti-
14 - 41
sation

6.2.16 15-** Drive Information

Parameter
Parameter Description
Number
15 - 00
Operating Time
15 - 01
Running Hours
15 - 02
kWh Counter
15 - 03
Power Up's
15 - 04
Over Temp's
15 - 05
Over Volt's
15 - 06
Reset kWh Counter
15 - 07
Reset Running Hours Counter
15 - 30
Fault Log: Error Code
15 - 40
GE Drive Type
15 - 41
Power Section
15 - 42
Voltage
15 - 43
SW ID Control Card
15 - 46
Frequency Converter Ordering No
15 - 48
Keypad Id No
15 - 51
Frequency Converter Serial Number
52
Default Value
2 Setup
[0] Off
1 set-up
[39] Start command
1 set-up
[40] Drive stopped
1 set-up
[0] Do not reset
1 set-up
[0] Disabled
1 set-up
[1] ApproxEqual
1 set-up
0
1 set-up
0 s
1 set-up
[0] False
1 set-up
[0] Disabled
1 set-up
[0] False
1 set-up
[0] Disabled
1 set-up
[0] False
1 set-up
[0] False
1 set-up
[0] Disabled
1 set-up
Default Value
2 Setup
[1] 4.0 kHz
All set-ups
[1] On
All set-ups
[0] Trip
All set-ups
[0] Manual reset
All set-ups
10 s
All set-ups
[0] Normal operation
1 set-up
[0] Trip
All set-ups
66 %
All set-ups
Default Value
2 Setup
0
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
[0] Do not reset
1 set-up
[0] Do not reset
1 set-up
0
1 set-up
1 set-up
1 set-up
1 set-up
1 set-up
1 set-up
1 set-up
1 set-up
DET-579A
AF-60 LP™ Micro Drive Operating Instructions
Change During
Conver-
Operation
sion
Index
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-1
TRUE
-1
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
Change During
Conver-
Operation
sion
Index
TRUE
-
FALSE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
0
Change During
Conver-
Operation
sion
Index
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Type
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Type
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
Uint8
Uint8
Uint8
Visible-
String
Visible-
String
Visible-
String
Visible-
String
Visible-
String
Visible-
String
Visible-
String