Talaris 177-0600 User Manual page 69

Table of Contents

Advertisement

Model: EV8650
Display
rFEEd
tAbLE
LASt
GuLP
oVEr
FAULt
CLEAn
CLEAn dd
CLEAn dEt
Lid
nEAr
n rdY det
TP05413002 Rev. 03
Copyright © 2009 by Talaris Ltd., Basingstoke (UK)
Display Messages (Continued)
Reason
The machine has stopped as a
result of a note handling problem
The machine has stopped as a
result of a invalid denominational
sized note.
A note from the previous bundle is
left in the transport.
Three or more notes have passed
through the machine together.
Only appears in value mode and
shows that a higher value than
originally requested has been
dispensed.
A fault has been detected in the
machine.
Dust from the banknotes is
obstructing the machine's sensors
This machine has stopped as a
result of dirt on the double detect
bearings or rollers.
This machine has stopped as a
result of dirt on one of the
detectors
The top of the machine has been
opened to allow for a jammed note
to be removed or for cleaning.
In dispense mode, the dispense
amount cannot be completed
because the denomination set is
larger than the remaining value
required.
A selected detector failed to start
properly. The icon for the affected
detector will flash.
This may be too dirt in the
transport path.
Display Messages
Solution
Remove all notes from the stacker
and repeat the count.
Remove all notes from the stacker,
remove the invalid domination
note and repeat count.
Remove notes and recommence
count.
Remove all the notes from the
stacker. Remove the suspect from
bundle and repeat the count.
Maybe adjust the feed gap setting
Replace notes with a lower value
in the hopper.
Switch off the machine and contact
your local agent's service
engineer.
Clean the machine internally.
See "Maintenance" on page 9.
Carry out the cleaning procedure
as shown. See "Maintenance" on
page 9.
Carry out the cleaning procedure
as shown. See "Maintenance" on
page 9.
Ensure the lid is closed correctly
and that both release latches are
secure. Press the START/STOP
key to clear the display.
Check and clean the transport.
Remove all notes and repeat the
count.
Check and clean the transport.
Remove all the notes and repeat
the count. Clean Detector
Page 61 of 62