left in the incubator can escape. Before the next incubating, it is necessary to clean the
filter and change the filter paper.
It is senseless to ignore little faults and hope that they can repaired later. The incubator
really has to work faultlessly.
Checkpoints before putting in the eggs:
• range of temperature, constant temperature
• air humidity, noise pollution
Incubator:
• horizontal position of the incubator
• measuring instruments ( thermometer)
• operating elements (controls)
• test run
• water sterilized by boiling
• trouble-free running
Applies to all menu items:
All values changed in the menu during operation are active with immediate effect.
If immediate implementation is not desired, the unit must be switched off at the main
switch for a few seconds.
The modified values become active after a time delay. All values in the individual menu
items refer to a 24 hour period.
Example: If the value in the turning menu is set to 6 times per day, the unit starts the first
turning period after 4 hours.
The automatic humidifier operates with a humidity sensor. The humidity sensor operates
solely on the basis of the set value.
If the automatic humidifier is not required, the set value for the moisture must be reduced
to the lowest setting (= 5 %).