Hussmann Excel Series Installation & Operation Manual page 7

Ultra low front rear load medium temperature dairy merchandisers
Hide thumbs Also See for Excel Series:
Table of Contents

Advertisement

P/N 0501930_G
SETTING REAR LOAD MERCHANDISER
The rear load merchandiser is installed in
a cooler wall . The illustrations below show
the relationship between the wall and the
merchandiser . The rear of the canopy extends
through the cooler wall . Note that the uprights
are forward of the wall with the merchandiser
end closing the gap .
Side View
Cooler Opening
W = Total Length of lineup without ends +
D5X-12URLE = 144
D6X-12URLE = 144
D5X-8URLE = 96
D6X-8URLE = 96
Opening Required in Cooler Wall
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
C
O
O
L
E
R
W
A
L
L
D6X-URLE 90
D5X-URLE 83
W
3
/
inch
4
1
/
in. (3670 mm)
2
1
/
in. (3670 mm)
2
3
/
in. (2448 mm)
8
3
/
in. (2448 mm)
8
Front View
MERCHANDISER LEVELING
Merchandisers must be installed level to ensure
proper operation of the refrigeration system
and to ensure proper drainage of defrost
water . During all steps of setting, joining and
leveling merchandisers, close attention to
position and operation must be maintained .
NOTE: b
egin lineup leveling from The
highesT poinT of The sTore floor
IMPORTANT
Do not remove shipping braces from
BI-FOLD DOORS
until the lineup is complete including joining
and end installation .
Bi-fold door set-up and operating
instructions begin on Page 1-17
Top View of D6X-URLE
D5X-URLE
Top View
1
/
in.
2
3
/
in.
4
Cooler Wall
Ultra Low Front Rear Load
1-3
.
Cooler Wall
1-in. Gasket
(apply top to
bottom of
end assembly)
Excel

Advertisement

Table of Contents
loading

This manual is also suitable for:

0501930_g05322560532257