Doran 300 Quick Start User Manual

Digital bench scale
Table of Contents

Advertisement

Model 300
Digital Bench Scale
INSTRUCTION MANUAL
DORAN SCALES, INC.
1315 PARAMOUNT PKWY.
1-800-262-6844
FAX: (630) 879-0073
http://www.doranscales.com
MANUAL REVISION: 2.1
MAN0193
3/8/2006
Made in USA

Advertisement

Table of Contents
loading

Summary of Contents for Doran 300

  • Page 1 Model 300 Digital Bench Scale INSTRUCTION MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVISION: 2.1 MAN0193 3/8/2006 Made in USA...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents ..................1 Introduction....................3 Quick Start User's Guide................4 Fig. 1: Model 300 Front Panel Layout ............... 4 Power Up: ........................4 Basic Weighing Operation:................... 4 Turn Off: (Battery option only) ..................4 Controls and Display Operation: .................. 4 Zero:..........................
  • Page 3 "F0" Format: ......................23 "2d" Format: ......................23 "SSP" format: ......................23 Table 4: Standard Doran serial protocol..............24 Table 5: SMA serial protocol ................... 25 Table 6: Toledo serial protocol ................26 Table 7: Fairbanks and UPS serial protocol ............27 Table 8: NCI serial protocol..................
  • Page 4: Introduction

    With ease of use and setup in mind, the scale is simple to set up and ready to use. The Model 300 offers many features. A few of these features are listed below: NTEP certification for Class III installations to 5,000d.
  • Page 5: Quick Start User's Guide

    Quick Start User's Guide Fig. 1: Model 300 Front Panel Layout Power Up: Connect the Model 300 to a compatible power source. Or, press and release ZERO to turn on, for scale with battery option. Basic Weighing Operation: 1) Remove all items from the scale platter.
  • Page 6: Zero

    The Model 300 can be used while recharging the battery. A full recharge takes place in four hours, whether the scale is on or off, in fact the Model 300 can be used with the AC charger cord plugged in on a continuous basis.
  • Page 7: Low Battery Indication: (Optional)

    Be sure the AC power is not excessively noisy - this can occur if large inductive loads, such as solenoids or motors, are on the same power line. The Model 300 has a filtered power supply to reduce the effects of normal line noise, but they cannot limit severe fluctuations.
  • Page 8: Quick Setup Guide

    Quick Setup Guide Load Cell and Power Connections: Load cell connections are made through a terminal block located at the bottom center of the main PC. Board (Fig. 2). The power cord connects to a connector adjacent to the transformer. These connections are accessible by removing the scale platter and access cover.
  • Page 9: Calibration

    Remote Switch GND. Remote Display Fig. 3: Remote Push Button Connections Calibration: 1) Enter Calibration mode by pressing the CAL button (S1 or S5) (see Fig. 4). Press and release the UNITS button (S2 or S6) until "CAL 0" appears on the display. Place scale platter back on top of platform.
  • Page 10: Analog Setup

    NOTE: Scales calibrated at 10% of capacity are more likely to have significant errors at full capacity than are scales calibrated at 25% or 50%. Doran Scales recommends that all scales be calibrated at full capacity whenever possible. 10% calibration should not be used when calibrating scales for legal for trade applications.
  • Page 11: Detailed Parameter Setup

    Detailed Parameter Setup The Model 300 has 20 setup and calibration parameters, which can be accessed through the scale's Calibration Setup Menu. Entering and Exiting the Calibration Setup Menu: To enter the Calibration Setup Menu. Remove the two screws mounting access cover.
  • Page 12: Changing A Parameter

    UNITS to go to the next menu item. Quick Review of Setup Parameters: Setup parameters for the Model 300 may be quickly reviewed without opening the scale. Remove power and press and hold the ZERO button while you apply power.
  • Page 13: Setup Menus Explained

    Setup Menus Explained (In order of occurrence) Calibration Setup Menu m.A. d.o. For. t.o.d. C.P. A.P.1 A.P.2 xxxxxx 0.25 UnitS P.b. r.P.b. xxxxxx donE 14.4 lb oz...
  • Page 14: Capacity Setup Menu

    Capacity Setup Menu Capacity Select Menu Allows the selection of scale capacity. 50 pounds 100 pounds 150 pounds 1) No lb-oz display for this capacity in precision resolution. 2) No lb-oz display for this capacity in super precision resolution.
  • Page 15: Calibration Menu

    (note: XXXXXX will be the dialed in weight value. * NOTE: For maximum accuracy, Doran Scales recommends that all scales be calibrated at full capacity. When location or installation make it difficult to bring full capacity weights to the scale, calibration with as...
  • Page 16: Digital Filter Setup Menu

    Digital Filter Setup Menu Averaging mode Determines the number of samples to average Stabil-izer © auto averaging. All readings are averaged. Display updates 10 times a second. Stabil-izer © auto averaging. All readings are averaged. Display updates 9 times a second. ©...
  • Page 17: Motion Aperture Setup Menu

    Motion Aperture Setup Menu m.A. * Motion aperture * Determines how many divisions consecutive readings must change before the scale is considered in motion. 1 division change must be seen to enter motion. 3 division change must be seen to enter motion. 5 division change must be seen to enter motion.
  • Page 18: Printer Data Output Setup Menu

    Printer Data Output Setup Menu d.o. Data Output Mode Determines when serial data will be sent. t.o.d. Transmit on demand. Print when the PRINT button is pressed. C.P. Continuous Print. Print when display is updated. A.P.1 Auto Print 1. Print once only when scale goes stable. A.P.2 Auto Print 2.
  • Page 19: Serial Data Handshaking Setup Menu

    Serial Data Handshaking Setup Menu Serial Data Output Handshaking Selects the type of serial data handshaking used. (See the Data Communication section for details) No handshaking is used. Data is sent when ready, receiving device (printer) must be fast enough to keep up with the data.
  • Page 20: Push-Button Function Setup Menu

    Push-button Function Setup Menu P.b. Push Buttons Configures the active push button functions. UNITS, PRINT enabled PRINT enabled only. UNITS enabled only. UNITS, PRINT disabled. Remote Push-button Configuration Menu r.P.b. Remote Push Button (P2 – pins 3 and 4) Configures the Remote Switch to perform one of the three front panel functions.
  • Page 21: Unit On Timer (Battery Only)

    Unit On Timer (Battery only) Selects the time value that the unit will remain on Unit will remain on, On timer is off 30 second "On timer" 1 minute "On timer" 1 minutes 2 minutes 3 minutes 5 minutes 10 minutes 30 minutes NOTE: The "On Timer"...
  • Page 22: Data Communications

    Data Communications Introduction to data communications: In the Model 300 data is sent to a printer or computer by using "asynchronous serial data communications." Data is broken up and sent one piece at a time to the printer or computer. In spite of this apparent simplicity, a basic understanding of serial data communications is needed when setting up the scale.
  • Page 23: Printer Modes

    "Ctrl-Q" is received. To use this mode, the RTX line of the scale is tied to the TXD line of the receiving unit. Printer Modes: The Model 300 offers four different print control modes. These modes dictate when printer data is sent. Transmit on demand (tod): In this mode, scale data is transmitted whenever the print button is pressed, the remote print button is pressed, or a print request is received from the serial port.
  • Page 24: Data Output Format

    Data output format: In order for the serial data sent from the scale to be useful, the data must be organized so that it is easy to read. To accomplish this, the scale arranges the displayed data with additional text to indicate the active units and to indicate the presence of motion during the reading.
  • Page 25: Table 4: Standard Doran Serial Protocol

    <CR> carriage return (hex 0D) (control-M) <LF> line feed (hex 0A) (control-J) Scale changes units Zeros scale Turns on serial handshaking (hex 11, ctrl-Q) scale output disabled XOFF Turns off serial handshaking (hex 13, ctrl-S) scale output enabled Table 4: Standard Doran serial protocol...
  • Page 26: Table 5: Sma Serial Protocol

    ( will reset B about command to response #1 ) <LF>B<CR> <LF><xxx>:<yyyyyy><CR> About Command Response “B” <xxx> 1 response “MFG” manufacturer <yyyyyy> “Doran Scales, Inc.” <xxx> 2 response “MOD” model number <yyyyyy> 300 <xxx> 3 response “REV” software revision <yyyyyy> SW005902 <xxx>...
  • Page 27: Table 6: Toledo Serial Protocol

    Command Scale Response Description <STX><xxx.xx><CR> Standard Scale Response Message <STX> start of text (hex 02) (control-B) <STX>?<status byte><CR> Prints current weight and resolution <xxx.xx> weight data (fixed field of 5 digits plus decimal. If in Legal for Trade mode, 5 digits plus decimal & polarity) ?<status byte>...
  • Page 28: Table 7: Fairbanks And Ups Serial Protocol

    Command Scale Response Description <CR> <p><xxx.xx><SP><uu><SP><mm> Standard Scale Response Message <SP><SP><CR><LF><EOT> <p> polarity “-“ or “ “ <xxx.xx> weight data (fixed field of 5 digits with decimal point) <CR><ETX> <SP> space “ “ (hex 20) <uu> current units (“lb“, “kg“, “oz“, “g “) <mm>...
  • Page 29: Specifications And Interconnect Data

    Specifications and Interconnect Data Specifications: Model 300 Resolution: 5,000d in precision mode Power Supply: 115/230 VAC 115/230 VAC 50/60 Hz 50/60 Hz 6V Battery Display: 6 digit LED. 0.56" high Displayed units: lb, kg, oz, g and lb oz Capacities:...
  • Page 30: Table 11: P2 Options Connections

    PIN # TITLE CTS for Hardware Handshaking RTX for Software Handshaking Remote Switch High Remote Switch Ground RS232 Signal Ground Table 11: P2 Options Connections PIN # TITLE Neutral Ground Table 12: J1 Power Connections PIN # TITLE Zero Switch Ground Zero Switch High Units Switch Print Switch...
  • Page 31: Fig. 6: P6 Rs232 Output Db9 Connector

    Fig. 6: P6 RS232 Output DB9 Connector RS232 Output DB9 Female connector Function RXD/CTS Signal GND Table 14: Serial Output pin description...
  • Page 32: Troubleshooting

    Troubleshooting General problem resolution: Problem: What to Do or Check: Weight reading will not Make sure that there is nothing caught in the platform repeat or scale does not under or around the load cell or spider interfering with return to zero when weight its movement.
  • Page 33: Resetting The Scale Parameters

    Doran Scales authorized dealer. Resetting the scale parameters: If at some point the Model 300, user wishes to return the setup parameters to factory default, follow these steps. WARNING: Defaulting the scale will require recalibration.
  • Page 34: Scale Messages

    Scale Messages: Message Meaning "donE" The scale has successfully completed the Function complete. requested action. "Abort" The requested action has been canceled prior to Aborted Function. completion. "SAVEd" The scale has successfully store and verified Parameter value saved. parameter value in nonvolatile memory. Error messages: Error Message What to Do or Check:...
  • Page 35: Application Note

    If the UPS On-Line program is not installed, power up the scale and connect the serial port on the back of the Model 300 to an available PC serial port using a standard straight through DB9 Male to Female cable. Next, install the UPS On-Line program as per instruction on the UPS installation CD.
  • Page 36 Scale Configuration: Every Model 300 ships from Doran ready to be connected to the UPS On-Line program. The Model 300 must be set to the following parameters: = C8 Averaging mode set to 8 readings d.o. = t.o.d. Data Output Mode is set to Transmit On Demand For.
  • Page 37: Warranty Statement

    LIMITED WARRANTY STATEMENT DORAN SCALES, INC. warrants its products to be free from defects in material and workmanship for a period of one (1) year from date of shipment. Any product found to be defective within this time period may be returned to DORAN’s factory, freight prepaid, with prior return...