Advertisement

Instruction Manual
HT Lysing Homogenizer, HOHTDG
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Revision 3
02/22/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HOHTDG and is the answer not in the manual?

Questions and answers

Summary of Contents for OHAUS HOHTDG

  • Page 1 Instruction Manual HT Lysing Homogenizer, HOHTDG 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com Revision 3 02/22/2018...
  • Page 2: Package Contents

    United States call toll-free 1-800-672-7722 ext. 7852 between 8:00 AM and 5:00 PM EST. Tube Rack An OHAUS product service specialist will be available to provide assistance. Outside the Allen wrench USA, please visit our web site, www.ohaus.com to locate the Ohaus office nearest you. Wrench Power cord Serial Number: _______________________________________________________...
  • Page 3: Installation

    Non-Operating Storage: Temperature: -20 to 65°C (-4 to 149°F) Upon receiving the Ohaus HT Lysing Homogenizer, check to ensure that no damage has Humidity: 20% to 85% relative humidity, non-condensing occurred in shipment. It is important that any damage that occurred in transport is detected at the time of unpacking.
  • Page 4: Safety Instructions

    Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Ohaus Corporation could void the user’s authority to operate the equipment.
  • Page 5: Specifications

    PecificationS Overall dimensions (L x W x H): 17.5 x 11.5 x 20.5” (44.3 x 28.8 x 51.8cm) Electrical (50/60 Hz): 120 volts AC: 3.2 amps, 450 watts 230 volts AC: 2.1 amps, 450 watts Fuses: 120 volts, 5mm x 20mm, 6.3 amp slo-blow fuse (250V Rated) 230 volts, 5mm x 20mm, 3.15 amp slow blow fuse...
  • Page 6 - Ht l ontrol anel ySing omogenizer The front panel of the HT Lysing Homogenizer contains all the controls and displays E. Time Display: Displays the set time (before the unit is started) or remaining time needed to operate the unit (once unit is running or if the unit is paused).
  • Page 7: Perating I Nstructions

    Perating nStrUctionS IMPORTANT: This unit is designed for intermittent use only. After every 10 minute cycle d. Place sample under the clamp. it must have at least 1 minute cool down period. Before processing any samples, it is e. Tighten by turning the handle clockwise until tight. advisable to perform a dry run with your plates or tubes with appropriate grinding material i.
  • Page 8 Program 5 Cryogenically Polycar- 1600rpm 1 minute switch the unit off and contact your Ohaus representative for repairs. Frozen Samples bonate d. When the unit is not being used flip the ON/OFF power switch to the OFF position. 4mL &...
  • Page 9 The homogenizer is now ready to mount in a new location. Never run the homogenizer without the rubber suction cup feet firmly attached. If damaged, replacement feet are available from your Ohaus representative.
  • Page 10: Troubleshooting

    2. Cycle power by turning the ON/OFF switch to the Off position, leaving it for 30 seconds and then switching it back to the ON position. If this does not fix your issue, contact your Ohaus representative. This Error code means that the unit “sees” a speed that is 1.
  • Page 11 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com *30391489* SAP P/N: 30391489 P/N: 530150-00 © 2018 OHAUS Corporation, all rights reserved...

This manual is also suitable for:

Ht lysing homogenizer