OHAUS Frontier FC5706 User Manual
Hide thumbs Also See for Frontier FC5706:

Advertisement

TM
Frontier
Centrifuge User Guide
For FC5706, FC5707, FC5513, FC5515/R, FC5714,
FC5718/R, FC5816/R, FC5916/R
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Advertisement

Table of Contents
loading

Summary of Contents for OHAUS Frontier FC5706

  • Page 1 Frontier Centrifuge User Guide For FC5706, FC5707, FC5513, FC5515/R, FC5714, FC5718/R, FC5816/R, FC5916/R 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com...
  • Page 3: Definition Of Signal Warnings And Symbols

    Benchtop Centrifuges EN-1 1. INTRODUCTION 1.1 Description Thank you for choosing this OHAUS product. All symbols indicate safety instructions and points to potential dangerous situations. Please read the manual completely before using the Frontier centrifuge to avoid incorrect operation. 1.2 Definition of Signal Warnings and Symbols Safety notes are marked with signal words and warning symbols.
  • Page 4: Installation Notes

    EN-2 Frontier Benchtop Centrifuges 2. INSTALLATION NOTES Placed the centrifuge on a stable and horizontal benchtop surface.  Allow access to a dedicated power connection as indicated by the name plate.  Avoid exposing the equipment to direct sunlight or heating devices close-by. ...
  • Page 5: General Operations

    Frontier Benchtop Centrifuges EN-3 2.2 Buttons Functions of buttons on the control panel are listed as below. If a setting is activated by pressing the corresponding button or combination, the display of the parameter will start flashing. Speed and RCF Temperature = Toggle between RPM and RCF;...
  • Page 6 EN-4 Frontier Benchtop Centrifuges 2.4 Installation the rotors FC5706 Clean the drive shaft as Place the rotor onto the drive shaft. Make sure well as the collet with a that the rotor is fully clean, grease-free piece of installed onto the motor cloth.
  • Page 7 Frontier Benchtop Centrifuges EN-5 d. Put on and secure the lid for the rotor before centrifugation Screw-on lid Snap-on lid 2.5 Loading samples for angle rotors Rotors must be loaded symmetrically and with equal weight. The adapter may only be loaded with the compatible containers.
  • Page 8: Safety Precautions

    3.2 Rotor and accessories Only OHAUS original rotors and accessories shall be used. Any other use or intended use is considered improper. OHAUS is not liable for damage resulting from improper use.
  • Page 9: Measures For Operational Safety

    Frontier Benchtop Centrifuges EN-7 3.5 Measures for operational safety Do not attempt to run the centrifuge with the lid open.  Do not override or disable the safety interlock.  Do not unscrew the two halves of the housing.  Dry off any liquid spills immediately! The instrument is not watertight.
  • Page 10 Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. For disposal instructions in Europe, refer to www.ohaus.com/weee. Thank you for your contribution to environmental protection.
  • Page 11 Unintentional Radiator per 47CFR Part B Trade Name: OHAUS CORPORATION Model: FC Party issuing Supplier’s Declaration of Conformity: Ohaus Instruments (Changzhou) Co., Ltd. Responsible Party – U.S. Contact Information: Ohaus Corporation FCC Compliance Statement: Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.