Download Print this page

Servicing The Engine - Exmark TURF TRACER X SERIES Setup Instruction

Advertisement

DANGER
Charging or jump starting the battery may produce
explosive gases. Battery gases can explode causing
serious injury.
• Keep sparks, flames, or cigarettes away from
battery.
• Ventilate when charging or using battery in an
enclosed space.
• Make sure venting path of battery is always open
once battery is filled with acid.
• Always shield eyes and face from battery.
DANGER
Battery electrolyte contains sulfuric acid, which is
poisonous and can cause severe burns. Swallowing
electrolyte can be fatal or if it touches skin can
cause severe burns.
• Wear safety glasses to shield eyes, and rubber
gloves to protect skin and clothing when
handling electrolyte.
• Do Not swallow electrolyte.
• In the event of an accident, flush with water and
call a doctor immediately.
1. Check the voltage of the battery with a digital
voltmeter. Locate the voltage reading of the battery
in the table below and charge the battery for the
recommended time interval to bring the charge up
to a full charge of 12.6 volts or greater.
Important: Make sure the negative battery
cable is disconnected and the battery charger
used for charging the battery should have
an output of 16 volts and 7 amps or less to
avoid damaging the battery (see chart for
recommended charger settings). This is
especially important on Kohler EFI (Electronic
Fuel Injection) units. Failure to do so may
damage the ECU (Electronic Control Unit).
Voltage
Percent
Reading
Charge
12.6 or
100%
greater
12.4 – 12.6
75–100%
12.2 – 12.4
50–75%
12.0–12.2
25–50%
Maximum
Charging
Charger
Interval
Settings
No Charging
16 volts/7
Required
amps
30 Minutes
16 volts/7
amps
1 Hour
16 volts/7
amps
2 Hours
14.4 volts/4
amps
Percent
Voltage
Reading
Charge
11.7–12.0
0–25%
0%
11.7 or less
CAUTION
If the ignition is in the "ON" position there
is potential for sparks and engagement of
components. Sparks could cause an explosion or
moving parts could accidentally engage causing
personal injury.
Be sure ignition switch is in the "OFF" position
before charging the battery.
2. Connect the negative battery cable.
Note: If the positive cable is also disconnected,
connect the positive (red) cable to the positive
battery terminal first, then the negative (black) cable
to the negative battery terminal. Slip insulator boot
over the positive terminal.
Note: If time does not permit charging the battery,
or if charging equipment is not available, connect
the negative battery cable and run the vehicle
continuously for 20 to 30 minutes to sufficiently
charge the battery.
Positioning the Discharge
Deflector
Loosen two 5/16 inch nyloc nuts attaching discharge
deflector. Lower the discharge deflector into position.
Retighten nyloc nuts until chute is snug but can pivot
freely.

Servicing the Engine

The engine is shipped with oil; check oil level and if
necessary fill to the appropriate level. Exmark 4-Cycle
Premium Engine Oil is recommended; refer to the
Engine Owner's manual for an appropriate API rating
and viscosity.
Servicing the Hydraulic Oil
The machine is shipped with hydraulic oil in the
reservoir.
1. Run the machine for approximately 15 minutes to
allow any extra air to purge out of the hydraulic
system.
2
Maximum
Charging
Charger
Interval
Settings
3 Hours
14.4 volts/4
amps
6 Hours or
14.4 volts/2
More
amps

Advertisement

loading

This manual is also suitable for:

Turf tracer x series lpTurf tracer ttx691kaecaTtx24kaeca