  • Page 1 1505! Isolated Variable AC Line Supply !!!!!!! Instruction Manual...
  • Page 2 1505 ISOLATED VARIABLE AC LINE SUPPLY Instruction Manual ® !" !" !" !" !"#$ #$%"& '()*+%" %"& '()*+%" %"& '()*+%" %"& '()*+%" %"& '()*+%",+)' ,+)' ,+)' ,+)' ,+)' Global Specialties,LLC 22820 Savi Ranch Parkway Yorba linda,CA 92887 WWW.globalspecialties.com 800-572-1028 M-00116...
  • Page 3: Table Of Contents

    PCB Components FRONT PANEL ======================================================================= Reference Designator Part Description ======================================================================== OUTPUT SOCKETS SOCKET 1 European ( 230VAC ) TABLE OF CONTENTS SOCKET 2 American ( 115VAC ) SOCKET 3 SLBR4 ( Lekage Red ) SWITCHES SECTION DESCRIPTION PAGE NO. ON/OFF SPDT 1801 10A/230V DPDT Toggle 6A/250V INTRODUCTION FUSE...
  • Page 4: Introduction

    * C13 0.1µf 50V, ±20% CD ( Additional ) to protect against shock hazards. DIODES The 1505 can measure power line leakage current by means of a 1N4148 probe and a switch selected range of the output DPM. It can 1N4148 measure leakage currents upto 9.99 mA.
  • Page 5: Specifications

    PCB Components GLOBAL 1505 / 06 SW - 0396 SECTION - 2 ======================================================================= SPECIFICATIONS Reference Designator Part Description ======================================================================= INPUT VOLTAGE 115 VAC IC’S INPUT FREQUENCY 47Hz to 63Hz. 7660 S KA 741/ LM 741 OUTPUT : I : 0 to 130 VAC at 4AMP MAX.
  • Page 6: Description

    DESCRIPTION PART LIST INPUT AND OUTPUT TERMINATION : PCB Components GLOBAL 1505 / 06 SW - 0396 The unit works from 115VAC, 47Hz to 63Hz single phase supply ======================================================================= with internal tap selection facility. The input is provided through a...
  • Page 7: Operating Instructions

    CALIBRATION PROCEDURE FOR MODEL 1505 OPERATING INSTRUCTIONS Keep the Voltage knob to minimum position(ccw). Press push a) 1505 as Isolated Variable AC Supply. switch marked ' V ' Set output voltage to ‘0’ volt by turning the 'Set Voltage' knob to Switch on the power.
  • Page 8: Service

    FACTORY SERVICE AND REPAIR !!and TM trademarks are the property of INTERPLEX Global Specialties will service and repair this instrument free of charge for ELECTRONICS, INC, Unit No.2, Highland Industrial Centre a period of one full year, subject to the warranty conditions stated below.