1.11 Inverter POWERFUL Operation

Outline
In order to exploit the cooling and heating capacity to full extent, the air conditioner can be
operated by increasing the indoor fan rotating speed and the compressor frequency.
Detail
When the POWERFUL button is pressed, the fan speed and target temperature are converted
to the following states for 20 minutes.
Operation mode
COOL
DRY
HEAT
FAN
AUTO
A
Ex: POWERFUL operation in cooling
Note:
POWERFUL operation cannot be used together with ECONO or COMFORT AIRFLOW
operation.
Function and Control
Dry rotating speed + A rpm
Same as cooling / heating in
= 40 ~ 50 rpm (depending on the model)
Target temp.
18˚C
POWERFUL
ON
POWERFUL
OFF
Fan
A rpm
H tap
Set tap
Fan speed
H tap + A rpm
H tap + A rpm
H tap + A rpm
POWERFUL operation
It should be the lower limit of
cooling temperature.
20 minutes
Main Functions
Target temperature
18°C
Lowered by 2.5°C
31.5°C
The target temperature is
kept unchanged.
It counts 20 minutes also
in the remote controller.
Ending condition:
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.
(R19177)