VP-3 User's Manual
1. Introduction
Vapor Pressure
Range: 0 to 47 kPa
Resolution: 0.01 kPa
Accuracy:
Sensor measurement accuracy is variable across a
range of temperatures and RH. Refer to the chart below to
determine the accuracy specification for the VP-3 sensor:
General
Dimensions: 1.96 cm (dia) x 5.4 cm (h)
Power requirements: 3.6 - 15 VDC, 0.03mA quiescent, 4mA
during 300ms measurement
Output: RS232 (TTL) or SDI-12
5
Need help?
Do you have a question about the VP-3 and is the answer not in the manual?