Decagon Devices VP-3 Operating Manual page 21

Vapor pressure, temperature & relative humidity sensor
Table of Contents

Advertisement

VP-3 User's Manual
4. Connecting Sensors
NOTE: The acceptable range of excitation voltages is from
3.6-15 VDC. If you wish to read the VP-3 with the Campbell
Scientific Data Loggers, you will need to power the sensors
off of a 12V or switched 12V port.
If your VP-3 is equipped with the standard 3.5mm plug, and you
wish to connect it to a non-Decagon datalogger, you have two
options. First, you can clip off the plug on the sensor cable, strip
and tin the wires, and wire it directly into the datalogger. This has
the advantage of creating a direct connection with no chance of
the sensor becoming unplugged; however, it then cannot be
easily used in the future with a Decagon readout unit or
datalogger. The other option is to obtain an adapter cable from
Decagon. The 3-wire sensor adapter cable has a connector for
the sensor jack on one end, and three wires on the other end for
connection to a datalogger (this type of wire is often referred to
as a "pigtail adapter"). Both the stripped and tinned adapter cable
wires have the same termination as seen above; the white wire is
excitation, red is output, and the bare wire is ground.
17