Lennox AC13 -018 Installation Instructions Manual page 20

Table of Contents

Advertisement

START: Measure outdoor ambient temperature
USE WEIGH-IN METHOD
Weigh-in or remove refrigerant
based upon line length
If
refrigerant
is
REMOVED, retest to
confirm that unit is
properly charged.
If value is LESS than
shown, then REMOVE
refrigerant.
°F
Psig
°F
32
57.5
50
33
58.8
51
34
60.2
52
35
61.5
53
36
62.9
54
37
64.3
55
38
65.7
56
39
67.1
57
40
68.6
58
41
70.0
59
42
71.5
60
43
73.0
61
44
74.5
62
45
76.1
63
46
77.6
64
65
47
79.2
48
80.8
66
67
49
82.4
506109−01 10/08
ABOVE or
39ºF (3.8ºC)
and BELOW
SHº (Superheat) Values (+/−5ºF)
Wet Bulb (air entering indoor coil)
ºF*
50 52 54 56 58 60 62 64 66 68 70 72 74 76
40
15 18 20 23 26 29 32 34 38 41 43 46 48 51
45
13 16 18 21 24 27 30 33 36 39 41 44 46 49
50
11 14 16 19 22 25 28 31 34 37 39 42 44 47
55
9 12 14 17 20 23 27 30 33 36 38 40 42 44
60
7 10 12 15 18 21 24 27 30 33 35 38 40 43
65
-
6 10 13 16 19 21 24 27 30 33 36 38 41
70
-
-
7 10 13 16 19 21 24 27 30 33 36 39
75
-
-
-
6
9 12 15 18 21 24 28 31 34 37
80
-
-
-
-
5
8 12 15 18 21 25 28 31 35
85
-
-
-
-
-
-
8 11 15 19 22 26 30 33
90
-
-
-
-
-
-
5
95
-
-
-
-
-
-
100
-
-
-
-
-
-
105
-
-
-
-
-
-
110
-
-
-
-
-
-
115
-
-
-
-
-
-
* Dry−bulb temperature (ºF) of entering outdoor ambient air.
MORE or
LESS
Figure 38. HCFC−22 Superheat RFC Method
Table 4. HCFC−22 Temperature (°F) − Pressure (Psig)
Psig
°F
Psig
84.1
68
117.3
85.7
69
119.4
87.4
70
121.4
89.1
71
123.5
90.8
72
125.7
92.6
73
127.8
94.4
74
130.0
96.1
75
132.2
98.0
76
134.5
99.8
77
136.7
101.6
78
139.0
103.5
79
141.3
105.4
80
143.6
107.3
81
146.0
109.3
82
148.4
111.2
83
150.8
113.2
84
153.2
115.3
85
155.7
40ºF (4ºC)
and
ABOVE
BELOW
9 13 16 20 24 27 31
-
6 10 14 18 22 25 29
-
-
8 12 16 21 24 28
-
-
5
9 13 17 22 26
-
-
-
6 11 15 20 25
-
-
-
-
8 14 18 24
If value is MORE
than shown, then
ADD refrigerant.
°F
Psig
°F
86
158.2
104
87
160.7
105
88
163.2
106
89
165.8
107
90
168.4
108
91
171.0
109
92
173.7
110
93
176.4
111
94
179.1
112
95
181.8
113
96
184.6
114
97
187.4
115
98
190.2
116
99
193.0
117
100
195.9
118
198.8
101
119
102
201.8
120
103
204.7
121
Page 20
1. Confirm proper airflow across coil using figure 32.
2. Compare unit pressures with Table 5, Normal
Operating Pressures.
3. Use SUPERHEAT to correctly charge unit or to
verify the charge is correct.
4. Set thermostat to call for heat (must have a cooling
load between 70-80ºF (21−26ºC)
5. Connect gauge set.
6. When heat demand is satisfied, set thermostat to
call for cooling.
7. Allow temperatures and pressures to stabilize.
8. Measure the suction line pressure and use the use
value to determine saturation temperature (table
4):
SATº =_________
9. Record suction line temperature:
VAPº =_________
10. Subtract to determine superheat (SHº):
VAPº − _____ SATº ______ = SHº______
11. Record the wet bulb temperature (air entering
indoor coil):
WB =_______
12. Record outdoor ambient temperature.
13. Compare results with table to the left.
NOTE − Do not attempt to charge system where a
dash appears, system could be overcharged.
Superheat is taken at suction line service port.
Suction line superheat must never be less than 5ºF
at the suction line service port.
If
refrigerant
is
ADDED, retest to
confirm that unit is
properly charged.
Psig
°F
Psig
207.7
122
267.1
210.8
123
270.7
213.8
124
274.3
216.9
125
278.0
220.0
126
281.7
223.2
127
285.4
226.4
128
289.2
229.6
129
293.0
232.8
130
296.9
236.1
131
300.8
239.4
132
304.7
242.8
133
308.7
246.1
134
312.6
249.5
135
316.7
253.0
136
320.7
137
324.8
256.5
260.0
138
329.0
139
333.2
263.5
°F
Psig
140
337.4
141
341.6
142
345.9
143
350.3
144
354.6
145
359.0
146
363.5
147
368.0
148
372.5
149
377.1
150
381.7