Ratings; Site Preparation; Section 1 Ratings - Netspective 16Hi Installation Manuals

Web filter
Table of Contents

Advertisement

1.

Ratings

AC input voltage:
Input frequency range:
Rated input current:
2.

Site Preparation

Setup location, rack and appliance precautions
Elevated Operating Ambient Temperature ‐ If installed in a closed or multi‐unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration
should be given to installing the equipment in an environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
Always keep the rack's front door and all panels and components on the appliances closed when not servicing to
maintain proper cooling.
Reduced Air Flow ‐ Installation of the equipment in a rack should be such that the amount of air flow required for
safe operation of the equipment is not compromised. Leave enough clearance, approximately 25 inches in the front,
and 30 inches in the back of the rack to enable you to access appliance components and allow for sufficient air flow.
Mechanical Loading ‐ Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
ALL RACKS MUST BE MOUNTED SECURELY. Ensure that all leveling jacks or stabilizers are properly attached to the
rack. If installing multiple appliances in a rack, make sure the overall loading for each branch circuit does not exceed
the rated capacity.
Do not slide more than one appliance out from the rack at a time. Extending more than one appliance at a time may
result in the rack becoming unstable. Install your appliance in the lower part of the rack because of its weight and
also for ease in accessing appliance components.
Circuit Overloading ‐ Consideration should be given to the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Earthing ‐ Reliable earthing of rack‐mounted equipment should be maintained. Particular attention should
be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
Install near appropriate AC outlets, and Ethernet hubs or individual jacks. Be sure to install an AC Power Disconnect
for the entire rack assembly. The Power Disconnect must be clearly marked. Ground the rack assembly properly to
avoid electrical shock.
NetSpective Web Filter
100 ‐ 240V~
50/60 Hz
6.1‐2.6A (x2)
16Hi Hardware Installation Guide