Table 4 Specifications continued
EMC SPECIFICATIONS
Emissions (Broadband & Narrowband):
Immunity:
REGULATORY APPROVALS
UL:
CE:
The product conforms to the following
product specifications and regulations:
5 — SPECIFICATIONS
Designed to meet UN ECE/324 Addendum 9 Regulation 10 Revision 4 (6 March
2012) for an Electrical/electronic sub-assembly (ESA).
Designed to meet IEC 61000-4-2: Test level IV (8 kV contact discharge or 15
ESD:
kV air discharge) according to ISO 10605:2001, Table B.1.
Designed to meet 30 V/m (20MHz to 1 GHz) when tested per ISO 11452–2,
Radiated Imunity:
Absorber-Lined Chamber (single sample).
Designed to meet IEC 61000-4-4: Test level 4 (4 kV peak, 2.5 kHz repetition
Conducted Immunity:
rate).
UL recognition to UL 583
The product complies with the requirements of the EMC Standards and RoHS
directive 2011/65/EU (RoHS 2).
EMC: Radiated Emissions: UN ECE/324;
Radiated Immunity: ISO 11451-1 and ISO 11451-2, using the RF levels defined
in BS EN 13309:2010;
Electrical Transient Conduction: IEC 61000-4-4: Test level 4
(4 kV peak, 2.5 kHz repetition rate);
ESD: ISO 10605: 2001.
RoHS: RoHS directive 2011/65/EU (RoHS 2).