Curtis 3140 Manual – Nov. 2017
BDI_CTR_empty: The "empty" parameter for the charge-tracking-reset curve, in mV per cell.
BDI_OCR: The open-circuit reset value, in mV per cell.
BDI_integration_time: The integration time, in minutes.
B+_nominal: The nominal B+ system voltage, in volts, e.g. 24, 36, 48.
can_baud_rate_struct_length: This parameter indicates the number of CAN ports that have baud rate
can_baud_rate: This parameter is enumerated as follows:
can_node_id_struct_length: This parameter indicates the number of CAN ports that have Node ID
can_node_id: 0-127 indicating the node ID of the display.
can_pdo_timeout_period: 0-32767 indicates the time in milliseconds that the last CAN-commanded
P_User_1 ~ P_User_10: These objects are 32-bit general purpose non-volatile objects. These objects will be
pg. 12
definitions.
Value
-2
-1
0
1
2
3
4
definitions.
data will be displayed. If no PDO1_RX messages are received within this time, all icons
and the backlight will turn off, Hourmeter Enable will be set to zero (stopping the internal
hourmeter from counting), and the large text display will show "***" until the next
PDO1_RX message receipt. If the large text source is "BSoC", then the large text display
will continue to show the internal BSoC calculation.
If no PDO2_RX messages are received within this time and the small text source is set for
"CAN", the small text display will change to "******" until the next PDO2_RX message
receipt. Otherwise, the small text display will continue to show the internal hourmeter
value.
Note: If both PDOs time out, then the unit enters Pre-operational mode. When
this occurs, the display will go blank and the backlight will turn off.
stored in EEPROM if "save" is written to canopen_store_all_parameters.
Baud Rate
20k
50k
125k
250k
500k
800k
1M
4 — DEVICE PARAMETER OBJECTS